Chapter 4 Maintenance; Daily Inspection - Panasonic SF4B-F31G(V2) Instruction Manual

Light curtain type4 heavy-duty
Table of Contents

Advertisement

Chapter 4 Maintenance

<Reference>
When any errors are found, refer to "Chapter 5 Troubleshooting" and report the symptoms to the main-
tenance in charge. If the rectification method is not clear, please contact our office.
Please make a copy of this checklist, check each inspection item in the respective square, and file the list
for record.

4-1 Daily Inspection

Check list (Daily inspection)
Check
column
Dangerous parts of the machine cannot be reached without passing through the sensing area of
this device.
Some part of operator's body remains in the sensing area when operation is done with dangerous
parts of the machine.
The calculated safety distance has been maintained or exceeded during installation.
There is no damage to the safety guard or protective structure.
There is no defect, fold, or damage in the wiring.
The corresponding connectors have been connected securely.
No dirt or scratches exist on the light emitting surface.
The test rod is not deformed or defective.
The operation indicator (green) of the emitter and the OSSD indicator (green) of the receiver light
up when no object is present in the sensing area. The control output (OSSD 1 / 2) is in ON status.
At this time, the effect of external noise can be inspected. In case external noise affects the opera-
tion, remove its cause and reinspect.
The test rod (ø14mm for SF4B-F□G<V2>, ø25mm for SF4B-H□G<V2>, ø45mm for SF4B-A□G<V2>)
can be detected less than 1,600mm/sec. at three positions, directly in front of the emitter (A), midway
between the emitter and the receiver (B), and directly in front of the receiver (C).
The OSSD indicator (red) of the receiver and the operation indicator (red) of the emitter continue
to light up as long as the test rod is present in the sensing area from (A) to (C).
With the machine in the operating condition, the dangerous parts operate normally when no object
is present in the sensing area.
With the machine in the operating condition, the dangerous parts stop immediately when the test
rod is inserted into the sensing area at any of the three positions, directly in front of the emitter (A),
midway between the emitter and the receiver (B), and directly in front of the receiver (C).
The dangerous parts remain stopped as long as the test rod is present in the sensing area.
The dangerous parts stop immediately when the power supply of this device is turned OFF.
The control output (OSSD 1 / 2) must turn OFF when the emission halt input / reset input wire (pink)
is open (for manual reset: connected to 0V, +V). At this time, the effect of external noise can be
inspected. In case external noise affects the operation, remove its cause and reinspect.
Be sure to check the operation of the muting function before its use. Furthermore, check the state
of the muting lamp (cleanliness or brightness etc.).
74
Be sure to inspect the following items prior to operation and confirm that there is
no error.
Operating this device without inspection or in an error condition can result in
death or serious injury.
Inspection item
(A)
(B)
(C)
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
Test rod

Advertisement

Table of Contents
loading