Electrical Requirements - Whirlpool Cabrio W10164752A Use & Care Manual [Page 6]
A grounded electrical outlet located within 2 ft (610 mm) of either
side of the dryer. See "Electrical Requirements."
A sturdy floor to support the total weight (dryer and load) of
200 lbs (90.7 kg). The combined weight of a companion
appliance should also be considered.
Cold water faucets located within 4 ft (1.2 m) of the water fill
valves, and water pressure of 20-100 psi (138-690 kPa). You
may use the water supply for your washer using the "Y"
connector and short hose (if needed) which are provided.
20-100 psi (138-690 kPa) for best performance.
A level floor with a maximum slope of 1" (25 mm) under entire
dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the same
closet as a dryer.
Installation Clearances
The location must be large enough to allow the dryer door to open
fully.
Dryer Dimensions
43 / "
1
2
(1105 mm)
29
/ "
1
4
(743 mm)
//static-data2.manualslib.com/manual/190510/Whirlpool-Cabrio-W10164752a.html?page=6 (2 of 7)3/20/2018 3:41:43 AM
22
/ "
1
4
(565 mm)
29"
(737 mm)
Additional spacing is required if you exhaust out the rear of the
dryer to either the right or left side.
18"*
(457 mm)
1"
1"
29"
29
(25 mm)
(25 mm)
(737 mm)
(743 mm)
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation
must conform to the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal
Standard for Mobile Home Construction and Safety, Title 24, HUD
Part 280) or Standard CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust system hardware, which is available for
purchase from your dealer.
Mobile home Installation Kit Part Number 346764. See "Tools
and Parts" section for information on ordering.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
Electrical Requirements
WARNING
14" máx.*
(356 mm)
48 in.
*
2
(310 cm
2
)
3"*
(76 mm)
3"*
(76 mm)
24 in.
*
2
(155 cm
)
2
5"
1
/ "
(127 mm)
4
B
C