EXCEL 10 W7754K,P,Q,R,S,T,V FCU CONTROLLERS − INSTALLATION INSTRUCTIONS
Table 2. W7754 Controller: Overview of terminals and functions (by model)
term.
#
1+2
Removable plug; receiving/sending data on the L
BINARY INPUT (DI1), configurable (via the LNS plug-in) to read input from, e.g., a hardwired
3
window contact, occupancy sensor, etc.; suitable for dry contacts, only; max. voltage at open
contact = 5 Vdc
ANALOG INPUT (AI3), permanently configured to read input from a hardwired wall module's
4
temperature setpoint adjustment knob; enabled / disabled using the left DIP switch
ANALOG INPUT (AI2), permanently configured to read input from a hardwired wall module's
5
room temperature sensor (use NTC20k sensor, only; accuracy [w/o sensor] = 0.5 °C at 25 °C);
enabled / disabled using the left DIP switch
6
GND serving terminals 4, 5, 9, 10, and 11 (I/Os for wall module)
7
GND serving terminal 12 (AO1)
8
GND serving terminal 3 (DI1)
BINARY OUTPUT (LED), permanently configured to write output to switch the LED of a hard-
9
wired wall module ON/OFF; enabled / disabled using the left DIP switch; max. voltage = 5 Vdc;
max. current = 5 mA
ANALOG INPUT (AI1), permanently configured to read input on whether a hardwired wall
module's 3-speed fan control knob has been set to AUTO, OFF, LOW, MEDIUM, or HIGH and
10
whether its "occupancy override" button has been pressed; enabled / disabled using the left DIP
switch
BINARY INPUT (DI2), permanently configured to read input on condition (open/closed) of
11
window contact; enabled / disabled using the right DIP switch; suitable for dry contacts, only;
max. voltage at open contact = 5 Vdc
ANALOG OUTPUT (AO1), used (depending upon configuration via the LNS plug-in) to control a
12
variable speed fan or to control a proportional valve
A normally-open relay (Rel4), permanently configured to write output to switch a hardwired
13+14
electrical reheat coil ON/OFF; switching voltage = 24...230 Vac; switching current = 0.05...10 A
15
A common terminal for terminals 16, 17, and 18
A normally-open relay (Rel3), permanently configured to write output to a hardwired three-speed
16
(3)
fan, setting it to HIGH
A normally-open relay (Rel2), permanently configured to write output to a hardwired three-speed
17
(3)
fan, setting it to MEDIUM
A normally-open relay (Rel1), permanently configured to write output to a hardwired three-speed
(3)
18
fan, setting it to LOW
19
(4)(7)
Triac output (Triac1), perm. configured to write output to OUT1 & close hardwired valve
20
(4)(7)
Triac output (Triac2), perm. configured to write output to OUT1 & open hardwired valve
21
(4)(7)
Triac output (Triac3), perm. configured to write output to OUT2 & close hardwired valve
(4)(7)
22
Triac output (Triac4), perm. configured to write output to OUT2 & open hardwired valve
24 VAC common terminal for terminals 19 & 20; internally connected to terminal 24;
23
(3)(7)
W7754T4431, only: internally connected also to terminal 27
24 VAC common terminal for terminals 19 & 20; internally connected to terminal 23;
24
(3)(7)
W7754T4431, only: internally connected also to terminal 27
The "N" (25) & "L" (26) power supply terminals (removable plug); W7754Q: 24 VAC (20%),
25+26
50/60 Hz; W7754K,P,R,S,T,V: 230 VAC (-15%/+10%), 50/60 Hz
27
(7)
24 VAC / 200 mA auxiliary voltage; internally connected to terminals 23 & 24
28
(7)
A common terminal for terminal 27; internally connected to terminals 6, 7, & 8
(1)
The W7754K features an extra socket (2-pin connector located to the left of the terminal blocks) containing an output suitable for attachment to a solid-state relay
(use only Carlo Gavazzi RS1A23D25-P64; max. voltage = 12 VDC; max. current = 12 mA at 10 VDC) for low-voltage PWM control in high-current electrical reheat
applications. To enable it, term. 19 and 20 must be configured (via LNS plug-in) for "Heat" -> "PWM".
(2)
For AO1 (terminal 12) to be used to control a proportional valve, OUT1 (term. 19 and 20) must be configured (via LNS plug-in) for "PWM", and the fan must not
be configured for "variable speed fan".
(3)
If all three relays (term. 16, 17, and 18) are switched OFF, the 3-speed fan will likewise be switched OFF. Switching voltage = 24...230 VAC; switching current =
0.05...3 A (max. 3 A for all three relays together).
(4)
Switching voltage = 230 VAC (W7754K,P,R,S,V) or 24 VAC (W7754Q,T), max. switching current = 0.5 A; max. peak (10 sec) current = 1 A
(5)
For output for low-voltage PWM control of a solid-state relay (W7754K, only) to be used, these terminals must be configured (via LNS plug-in) for "Heat" ->
"PWM".
(6)
In order for AO1 (terminal 12) to be used to control a 6-way ball valve from Belimo, OUT1 must be configured for "Not USED," OUT2 (term. 21 and 22) must be
configured (via LNS plug-in) for "Changeover Mode" type "Floating Mid," and the fan must not use the analog output (no fan or 1...3-speed fan).
(7)
Total current draw of terminals 19 through 24 and 27 through 28 must not exceed 450 mA.
function
W
network
ON
ORKS
(2)
or to control a 6-way ball valve
3
K
P
Q
(1)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
--
--
--
X
X
X
X
X
X
X
X
X
X
X
X
--
--
--
(6)
--
X
X
X
X
X
X
X
X
X
X
X
X
X
X
--
(5)
X
X
--
(5)
X
X
--
X
X
X
X
X
X
X
X
X
X
X
230
230
24
VAC
VAC
VAC
--
--
--
--
--
--
model
R
S
T
V
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
--
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
--
X
X
X
--
X
X
X
X
X
--
X
X
X
--
X
X
X
--
X
X
X
--
X
--
X
--
X
X
X
X
X
--
X
--
X
X
X
X
X
X
X
X
X
X
X
X
230
230
230
230
VAC
VAC
VAC
VAC
--
--
X
--
--
--
X
--
EN1B-0304GE51 R0916M