Sony MVS-6520 User Manual page 117

Multi format switcher system with icp-series control panel
Hide thumbs Also See for MVS-6520:
Table of Contents

Advertisement

Setting the DME wipe position (Positioner)
1
Open the M/E-1 >DME Wipe >Modify menu (1165).
2
If the selected pattern is in 2-channel mode, in the <Ch
Select> group, select the corresponding channel.
You can select more than one channel at the same
time.
3
Press [Position] in the <Position> group, turning it on.
4
Set the following parameters.
No.
Parameter
Adjustment
1
H
Horizontal position
2
V
Vertical position
Display indications when multiple channels are
selected at the same time
The indications for the parameters show the settings
on channel 1. When you adjust the settings, this
changes the settings on channel 2 by the same amount.
To return the DME wipe pattern position to the
center of the screen
In the <Position> group, press [Center].
Displaying and moving the position of
DME wipe patterns
1
Open the M/E-1 >DME Wipe >Modify menu (1165).
Among the [Top Left], [Top Right], [Bottom Left],
and [Bottom Right] buttons in the <Position Select>
group, the button that is on indicates the current
display position of the DME wipe pattern.
2
Press [Position] in the <Position> group, turning it on.
3
If the selected pattern is in 2-channel mode, in the <Ch
Select> group, select the corresponding channel.
You can select more than one channel at the same
time.
4
In the <Position Select> group, press the button of the
destination, turning it on.
The DME wipe pattern displayed on the screen moves
to the position of the specified button.
Moving the relative position of DME wipe
patterns
In 2-channel mode, patterns are available whose relative
position can be moved.
1
Open the M/E-1 >DME Wipe >Modify menu (1165).
2
In the <Ch Select> group, select the target channels.
3
Press [Position] in the <Position> group, turning it on.
4
Set the following parameters.
No.
Parameter
Adjustment
4
Relative H
Relative movement in the
horizontal direction
5
Relative V
Relative movement in the vertical
direction
Setting the DME wipe pattern size (Size)
1
Open the M/E-1 >DME Wipe >Modify menu (1165).
2
If the selected pattern is in 2-channel mode, in the <Ch
Select> group, select the corresponding channel.
You can select more than one channel at the same
time.
3
Press [Size], turning it on.
4
Set the following parameter.
No.
Parameter
Adjustment
1
Size
Effect size
a) The effect size when [Size] is off is taken as 100.00%.
Display indications when multiple channels are
selected at the same time
The indications for the parameters show the settings
on channel 1. When you adjust the settings, this
changes the settings on channel 2 by the same amount.
Adjusting the DME wipe pattern cropping
(Crop)
1
Open the M/E-1 >DME Wipe >Modify menu (1165).
2
If the selected pattern is in 2-channel mode, in the <Ch
Select> group, select the corresponding channel.
You can select more than one channel at the same
time. Some patterns need no selection, as the setting in
the <Ch Select> group is fixed.
3
In the <Crop Mode> group, press [Crop], turning it on.
4
Set the following parameters.
a)
Basic DME Wipe Setting Operations
117

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents