  • Page 1 2M/E CONTROL PANEL ICP-6520 ICP-3000 3M/E CONTROL PANEL ICP-6530 MENU PANEL ICP-6511 INSTALLATION MANUAL 1st Edition...
  • Page 2 ! WARNING This manual is intended for qualifi ed service personnel only. To reduce the risk of electric shock, fi re or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualifi ed to do so. Refer all servicing to qualifi...
  • Page 3 When installing the installation space must be secured in consideration of the ventilation and service operation. . Do not block the ventilation slots at the left side and right side panels, and vents of the fans. . Leave a space around the unit for ventilation. .
  • Page 5: Table Of Contents

    Table of Contents Manual Structure Purpose of this manual ............2 (E) Related manuals ..............2 (E) Trademarks ................2 (E) 1. Installation 1-1. Operating Environment ..........1-1 (E) 1-2. Power Supply ............1-1 (E) 1-3. Installation Space ............1-2 (E) 1-3-1. External Dimensions ........1-2 (E) 1-3-2.
  • Page 6: Manual Structure

    Purpose of this manual This manual is the Installation Manual of following models. . 2M/E Control Panel ICP-6520/3000 . 3M/E Control Panel ICP-6530 . Menu Panel ICP-6511 This manual is intended for use by trained system and service engineers, and provides the information that is required to install (operating environment, installation space, connection information, etc.).
  • Page 7: Installation

    ICP-6520: 44 A peak, 10 A r.m.s. (240 V AC) +5 dC to +40 dC Operating guaranteed temperature: ICP-6530: 46 A peak, 11 A r.m.s. (240 V AC) Performance guaranteed temperature: +10 dC to +35 dC ICP-3000: 40 A peak, 10 A r.m.s. (240 V AC)
  • Page 8: Installation Space

    For ICP-6511 For customers in the U.S.A. and Canada  Power cord, 125 V 7 A (2.0 m) : ! 1-757-562-11  AC Adaptor For customers in the U.S.A. and Canada 1 Power cord, 125 V 0 A (2.4 m) : ! 1-575-131-82 AC Adapter 1-3.
  • Page 9 ICP-6530 1154 Unit: mm ICP-3000 Unit: mm 1-3 (E) ICP-6520/6530/3000/6511...
  • Page 10 ICP-6511 6-M3 Unit: mm 1-4 (E) ICP-6520/6530/3000/6511...
  • Page 11: Installation Space

    1-3-2. Installation Space When the ICP-6520/6530/3000 is recessed into a control console or similar, make holes as shown below into the control console with the following dimensions. For the procedure of installation to the control console, refer to Section 1-4. ICP-6520 Be sure to have an open space behind the cables of the connectors on the ICP-6520, shown as the “open space at A”...
  • Page 12 ICP-6530 1157 to 1160 ?0.5 1136.6 6-M4 ”Hole” 12Ф identical configuration Clearance hole of parts with the depth of 3 mm or more Unit: mm ICP-3000 823.6 to 826.6 ?0.5 803.2 6-M4 ”Hole” 12Ф identical configuration Clearance hole of parts with...
  • Page 13: Installing The Icp-6520/6530/3000

    1-4. Installing the ICP-6520/6530/3000 2. Remove the module covers on both sides. Module cover When installing the ICP-6520, ICP-6530 and ICP-3000 into the control console, be sure to install it with two Control panel persons or more. Install these by following the procedure described below.
  • Page 14 4. Remove the screw, then slowly move the cap (SW) in 6. Secure the control panel to the control console with the the direction of the arrow. screws. Number of screws Cap (SW) ICP-6530, ICP-3000: 6 pcs PSW3 x 8 ICP-6520: 4 pcs B4 x 6 B4 x 6 Cap (SW) 7.
  • Page 15 8. Attach the innermost module. 9. Attach the cap (L) and cap (R) with the screw respec- tively in the direction of the arrows. Then, attach the module covers in the direction of the Module arrows. PSW3 x 8 Cap (R) Cap (L) PSW3 x 8 Module cover...
  • Page 16: Installing Menu Panel

    1-5. Installing Menu Panel Installation The menu panel ICP-6511 can be installed to the monitor Connect the attached 50-pin cable to the menu panel, and arm compliant with VESA Standard using the adapter then perform the following steps. supplied with ICP-6511. See the dimensions for installation below.
  • Page 17: Setting The Switch Button Serigraph Labels

    1-6. Setting the Switch Button Serigraph Labels In the system using ICP-6520/6530/6511, the switch button serigraph label needs to be changed depend- ing on the configuration of the switcher to be used in combination. 1. Change of switch button serigraph label in combination of MVS-6520 and ICP-6520/6511 Change of switch button serigraph label is required when MVS-6520 and ICP-6520/6511 are combined.
  • Page 18 2. Change of switch button serigraph label in combination of MVS-6530 and ICP-6520/6511 Change of switch button serigraph label is required when MVS-6530 and ICP-6520/6511 are combined. ICP-6520 ICP-6511 Before change After change KEY1 DSK1 KEY2 DSK2 KEY3 DSK3 KEY4 DSK4 DSK5 DSK6...
  • Page 19 Before change After change Before change After change DSK1 DSK1 SHIFT /DSK5 DSK2 DSK2 /DSK6 DSK3 DSK3 K5-K8 /DSK7 TRANS TRANS DSK4 DSK4 /DSK8 TRANS As for 1 to 6, change the key top after changing the allocation in the setup menu. For the setup operation, refer to "Assigning 8-Keyer Buttons"...
  • Page 20 3. Change of switch button serigraph label in combination of MVS-6520 and ICP-6530/6511 Change of switch button serigraph label is required when MVS-6520 and ICP-6530/6511 are combined. ICP-6530 ICP-6511 Before change After change KEY1 DSK1 KEY2 DSK2 KEY3 DSK3 KEY4...
  • Page 21 4. Change of switch button serigraph label in combination of MVS-6530 and ICP-6530/6511 Change of switch button serigraph label is required when MVS-6530 and ICP-6530/6511 are combined. ICP-6530 ICP-6511 Before change After change KEY1 DSK1 KEY2 DSK2 KEY3 DSK3 KEY4...
  • Page 22 Before change After change Before change After change DSK1 DSK1 SHIFT /DSK5 DSK2 DSK2 /DSK6 DSK3 DSK3 K5-K8 /DSK7 TRANS TRANS DSK4 DSK4 /DSK8 TRANS As for 1 to 6, change the key top after changing the allocation in the setup menu. For the setup operation, refer to "Assigning 8-Keyer Buttons"...
  • Page 23: Matching Connectors And Cables

    Use the following connectors, cables or equivalents when connecting cables to the unit. Model name Panel indication Connector name Matching connector and cable ICP-6520 RJ-45 modular jack ICP-6530 UTIL RJ-45 modular jack ICP-3000 DEVICE1 to 4 USB Type A Use the USB cable that is commercially available on receptacle market.
  • Page 24: Input/Output Signals Of Connectors

    1-8. Input/Output Signals of Connectors DVI-D OUT: DVI-D (25-pin) Input and output signals of the connectors are as follows. 1-8-1. ICP-6520/6530/3000 (External View) MVS/UTIL: 1000BASE-T, RJ-45 (8-pin) Pin No. Signal name Function DATA2_ Digital video signal.(Red_) DATA2+ Digital video signal.(Red+) DATA 2/4 shield Shield DATA 4_...
  • Page 25: Icp-6511

    DEVICE (IN): USB (Type B) 1-8-2. ICP-6511 DVI-D IN: DVI-D (25-pin) (External View) (External View) DEVICE (OUT): USB (Type A) Pin No. Signal name Function DATA2_ Digital video signal.(Red_) DATA2+ Digital video signal.(Red+) DATA 2/4 shield Shield (External View) DATA 4_ No connection DATA 4+ No connection...
  • Page 26: Description Of On-Board Switches And Leds

    1-9. Description of On-board Switches and LEDs 1-9-1. ICP-6520/6530/3000 The number shown in the parentheses ( ) indicated the address on the circuit board. CA-86 board S1904 S1801 D1406 S1905 D2301 D1801 D2302 D1802 D2303 D1803 D2304 D1804 S1802 D1405 D1404 CA-86 board (Side A) D1801 (F-4): POR MON LED 0...
  • Page 27 D1804 (F-4): POR MON LED 3 CA-86 board status indication. Lit when LED 2 is lit, IC2001 operates normally, and HW Reset to CPU is cancelled. * All of the POR MON LED 0 to 3 are lit during normal operation.
  • Page 28 KY-688 board S301 D401 S300 KY-688 board (Side A) D401 (B-1): +5V-MAIN Power status indication. Lit when +5V-MAIN is supplied normally. Switch S300 (D-3): RESET Initializes the KY-688 board. S301 (E-1): SETTING1 Used for the production in the factory. Do not change the setting.
  • Page 29 KY-689 board S301 D401 S300 KY-689 board (Side A) D401 (E-2): +5V-MAIN Power status indication. Lit when +5V-MAIN is supplied normally. Switch S300 (D-3): RESET Initializes the KY-689 board. S301 (D-1): SETTING1 Used for the production in the factory. Do not change the setting.
  • Page 30 KY-690 board D401 S301 S300 KY-690 board (Side A) D401 (E-1): +5V-MAIN Power status indication. Lit when +5V-MAIN is supplied normally. Switch S300 (D-2): RESET Initializes the KY-690 board. S301 (E-2): SETTING1 Used for the production in the factory. Do not change the setting.
  • Page 31 KY-691 board D401 S301 S300 KY-691 board (Side A) D401 (H-1): +5V-MAIN Power status indication. Lit when +5V-MAIN is supplied normally. Switch S300 (F-2): RESET Initializes the KY-691 board. S301 (G-1): SETTING1 Used for the production in the factory. Do not change the setting.
  • Page 32 KY-692 board D403 S301 S300 KY-692 board (Side A) D403 (E-1): +5V-MAIN Power status indication. Lit when +5V-MAIN is supplied normally. Switch S300 (D-2): RESET Initializes the KY-692 board. S301 (E-2): SETTING1 Used for the production in the factory. Do not change the setting.
  • Page 33 KY-693 board S301 S300 D403 KY-693 board (Side A) D403 (D-3): +5V-MAIN Power status indication. Lit when +5V-MAIN is supplied normally. Switch S300 (E-1): RESET Initializes the KY-693 board. S301 (D-1): SETTING1 Used for the production in the factory. Do not change the setting.
  • Page 34 KY-694 board S301 S300 D401 KY-694 board (Side A) D401 (D-3): +5V-MAIN Power status indication. Lit when +5V-MAIN is supplied normally. Switch S300 (D-2): RESET Initializes the KY-694 board. S301 (D-1): SETTING1 Used for the production in the factory. Do not change the setting.
  • Page 35 KY-699 board S301 D403 S300 KY-699 board (Side A) D403 (C-1): +5V-MAIN Power status indication. Lit when +5V-MAIN is supplied normally. Switch S300 (C-3): RESET Initializes the KY-699 board. S301 (B-1): SETTING1 Used for the production in the factory. Do not change the setting.
  • Page 36: Icp-6511

    1-9-2. ICP-6511 The number shown in the parentheses ( ) indicated the address on the circuit board. KY-695 board D203 D204 KY-695 board (Side B) D203 (C-1): +7V LED Power status indication. Lit when +7V LED is supplied normally. D204 (A-3): +5V Power status indication.
  • Page 37 IF-1196 board S301 D301 D302 D303 D405 D401 D402 D403 S600 S601 S602 IF-1196 board (Side A) Switch S301 (A-1) D301 (A-1): DONE Used for the production in the factory. Do not change the Lit when the internal Init. of the touch panel IC is com- setting.
  • Page 38: System Connection

    Terminate with the supplied 75 Z terminators. LAN cable (straight type) Terminators are supplied in the product package. Cable with BNC connectors b) The figure shows the MVS-6530. c) The figure shows the ICP-6530. DVI cable USB cable 1-32 (E) ICP-6520/6530/3000/6511...
  • Page 39: Connection Example Of The Icp-3000 System

    1-10-2. Connection Example of the ICP-3000 System ICP-3000 Control Panel Camera Playback VTR CG video/key signal generator, etc. DVI-D AC power supplies IN 1 to 32 MVS-3000 Multi Format Switcher OUT 1 to 16 AC power supplies DEVICE Reference video signal Menu display monitor Video output monitor (program output, preview, multi viewer, etc.) Removable disk...
  • Page 40: Removing The Module

    1-11. Removing the Module The removal procedure of the module is the same for all models. 1. Remove the module covers on both sides. 2. Release the lock lever by pushing it in the direction of the arrow B using a flat screwdriver while pushing the portion A of the module.
  • Page 41 4. Pull out the power cord, or turn off the two power 6. To install, reverse the removal procedure. switches. After attaching the module (step 2), push the portion A of the module and check that the lock lever is Module securely locked in the direction of the arrow D.
  • Page 43: Service Overview

    Section 2 Service Overview 2-1. Troubleshooting Switched and indicators, etc. on the panel are not lit 2-1-1. ICP-6520/6530/3000 Flow3 Switched and indicators, etc. The status indication lamp A/B is not lit in green on the panel are not lit. Flow1 Check the item in Flow1 The status indication lamp Is the status indication lamp...
  • Page 44: Periodic Inspection And Maintenance

    This may have an adverse effect on performance and life of the machine. Cleaning of the fan every month is recommended. Contact your local Sony Sales Office/Service Center for information cleaning the fan. Air flow Air intake...
  • Page 45: Recovery Mode

    2-3. Recovery Mode Track ball If the track ball becomes dirty, it may result in adverse effects, typically the image does not move even though the A system operates in the mode in which the boot program track ball is manipulated. data of a CA-86 board is automatically restored when it has Cleaning the track ball every month is recommended.
  • Page 48 ICP-6520 (SY) ICP-6530 (SY) ICP-3000 (SY) Printed in Japan Sony Corporation ICP-6511 (SY) J, E 2012. 9 08 4-446-374-01 ©2012...

This manual is also suitable for:

Icp-6511Icp-6520Icp-3000

Table of Contents