Drive Backplane Connectors - Lenovo ThinkSystem SR950 7X12 Setup Manual

Table of Contents

Advertisement

Figure 56. RAID card connectors (type 2)
Table 31. RAID card connectors (type 2)
Callout
1
RAID flash power module (J14) connector
2
RAID connector for drive backplane 2 or 5 (SAS only)

Drive backplane connectors

The following illustration shows the internal connectors on the drive backplanes.
Note: Some cable connectors have locks or latches that must be disengaged to disconnect the cable.
There are two types of drive backplane used in the server: one that controls only SAS drives and one that
controls both SAS and NVMe drives. Cable routing for drive components is different for SAS and SAS/NVMe
drives:
• SAS drive backplane connectors
• SAS/NVMe drive backplane connectors
For information about drive backplane cable routing, see "Cable routing for drives" on page 29.
SAS drive backplane connectors
Figure 57. SAS drive backplane connectors
Table 32. SAS drive backplane connectors
Callout
1
Drive connector for SAS drives 0, 4, 8, 12, 16, and 20
2
Drive connector for SAS drives 2, 6, 10, 14, 18, and 22
3
Drive connector for SAS drives 1, 5, 9, 13, 17, and 21
Callout
3
RAID connector for drive backplane 1 or 4 (SAS only)
4
PCI connector to storage interposer
Callout
4
Drive connector for SAS drives 3, 7, 11, 15, 19, and 23
5
SAS signal from RAID card
6
Backplane power from interposer
Appendix B. Component reference