Description, Specifications And Standard Equipment Description; Specifications - RIDGID micro CD-100 Operator's Manual

Combustible gas detector
Hide thumbs Also See for micro CD-100:
Table of Contents

Advertisement

micro CD-100 Combustible Gas Detector
serious personal injury. The micro CD-100 does not specifi-
cally identify the combustible gas type or exact concentration.
• Always turn on and calibrate the gas detector in an area
known to be free of combustible gases. Calibration in an
area containing combustible gas will result in incorrect calibra-
tion and lower than actual readings. This could result in com-
bustible gases not being detected.
If you have any question concerning this RIDGID
• Contact your local RIDGID distributor.
• Visit www.RIDGID.com or www.RIDGID.eu to find your local
RIDGID contact point.
• Contact Ridge Tool Technical Service Department at rtctechser-
vices@emerson.com, or in the U.S. and Canada call (800) 519-
3456.
Description, Specifications
And Standard Equipment
Description
The RIDGID
®
micro CD-100 Combustible Gas Detector is a gas leak
locating tool that is used to identify the presence of and isolate the
source location of combustible gases such as methane, propane,
butane, ammonia and others ( see page 5 for a more complete list)
by indicating relative gas concentrations. Even low levels of com-
bustible gas can be detected in seconds.
The micro CD-100 detects gas concentrations through the use of
an internal sensor. This sensor is heated during operation. As the
heated sensor interacts with gases, the unit immediately indicates to
the user that combustible gases are present. The micro CD-100 in-
dicates the presence of combustible gases with visual, audio and
vibration feedback mechanisms. There are five (5) threshold levels
of measurement within two (Low and High) settings of sensitivity.
4
When the tool senses the presence of a combustible gas, it will tell
the operator by blinking the appropriate light(s), triggering the ap-
propriate audible alert or providing the appropriate vibration alert.
The micro CD-100 comes equipped with an attached flexible 16"
probe hose.

Specifications

Visual Alert ...................................5 Red LEDs: Gas Measuring
®
product:
Audible Alert(85 db) ......................Loud Audible Ticking Rate
Vibration Alert ...............................Standard
Sensitivity*......................................40 ppm (methane)
Response Time ..............................< 2 Seconds
Range.............................................0 – 6400 ppm (methane)
Sensitivity* Level
(methane) (HIGH) .........................5 Levels:
Sensitivity* Level
(methane) (LOW)..........................5 Levels:
Warm Up Calibration ....................Automatic
Warm Up Time..............................50 Seconds Max
Operating Buttons.........................Five: Power ON/OFF, High
Batteries .......................................4 x "AA"
Low Battery Status .......................Low and High Sensitivity LED
Sensor Connection .......................Plug-In
*Sensitivity level may vary for other gases.
Levels; Sensitivity Visual Alert
(w/Continuous Modulation
Proportional to Gas Level)
40/80/160/320/640 ppm
400/800/1600/3200/6400 ppm
Sensitivity, Low Sensitivity,
Audio Alerts, Vibration Alerts
Solid

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents