Item
Panel test mode
10. Single TONE
Adj item:
Deviation ad-
[TONE]
just
Adjust:[.]
[Narrow]
Deviation meter
LPF : 15kHz
HPF : OFF
PTT : ON
Press [
] key to
store the adjustment
value.
Adj item:
[Wide]
[TONE]
Adjust:[...]
PTT : ON
Press [
] key to
store the adjustment
value.
11. MSK Devia-
1) Adj item:[MSK]
tion adjust
Adjust:[.]
[Narrow]
Deviation meter
LPF : 15kHz
HPF : OFF
PTT : ON
Press [
store the adjust-
ment value.
[Wide]
1) Adj item:[MSK]
Adjust:[...]
PTT : ON
Press [
] key to
store the adjust-
ment value.
12. CWID Devia-
Adj item:
tion adjust
[CWID]
[Very Narrow]
Adjust:[]
Deviation meter
LPF : 15kHz
HPF : OFF
PTT : ON
Press [
] key to
store the adjustment
value.
ADJUSTMENT
PC test mode
1) Adj item: [Single
Tone Deviation
(Analog Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press [Trans-
mit] button. Press
[Apply] button to
store the adjustment
value.
1) Adj item: [Single
Tone Deviation
(Analog Wide]
PTT: Press [Transmit]
button. Press [Apply]
button to store the
adjustment value.
1) Adj item: [MSK
Deviation (Analog
Narrow]
Deviation meter
LPF: 15kHz
HPF: OFF
] key to
PTT: Press [Trans-
mit] button. Press
[Apply] button to
store the adjustment
value.
1) Adj item: [MSK
Deviation (Analog
Wide]
PTT: Press [Transmit]
button. Press [Apply]
button to store the
adjustment value.
1) Adj item: [CW ID
Deviation (NXDN
Very Narrow)] 
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press [Trans-
mit] button. Press
[Apply] button to
store the adjustment
value.
NX-720H(G)/720H
Measurement
Test-
Termi-
Unit
Unit
equipment
nal
Deviation
ANT
meter
Oscillo-
scope
Deviation
ANT
meter
Oscillo-
scope
Deviation
ANT
meter
Oscillo-
scope
Adjustment
Parts
Method
[Panel tun-
Write the value
ing mode]
513
(Reference value)
[
],[
]
[PC test
mode]
[
],[
]
Write the value
513
(Reference value)
[Panel tun-
Write the value
ing mode]
513
(Reference value)
[
],[
]
[PC test
mode]
[
],[
]
Write the value
513
(Reference value)
[Panel tun-
Write the value
ing mode]
376
[
],[
]
(Reference value)
[PC test
mode]
[
],[
]
Specifi cations/
Remarks
1.50kHz±0.05kHz
3.00kHz±0.05kHz
1.50kHz±0.05kHz
3.00kHz±0.05kHz
1.00kHz±0.10kHz