Kenwood NX-720H(G) Service Manual page 48

Vhf digital transceiver
Hide thumbs Also See for NX-720H(G):
Table of Contents

Advertisement

NX-720H(G)/720H
Item
Panel test mode
4. Maximum De-
Adj item:
viation (NXDN)
[NDEV]
adjust
Adjust:[.]
Deviation meter
[Narrow]
LPF : 3kHz
HPF : OFF
PTT : ON
Press [
] key to
store the adjustment
value.
[Very Narrow]
Adj item:
[NDEV]
Adjust:[]
PTT : ON
Press [
] key to
store the adjustment
value.
48
ADJUSTMENT
Measurement
PC test mode
Test-
equipment
1) Adj item: [Maximum
Deviation
Deviation (NXDN
meter
Narrow)]
Oscillo-
Deviation meter
scope
LPF: 3kHz
HPF: OFF
PTT: Press [Trans-
mit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [Maximum
Deviation (NXDN
Very Narrow)]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
Adjustment
Termi-
Unit
Unit
Parts
nal
[Panel tun-
ing mode]
[
],[
]
[PC test
mode]
[
],[
]
Specifi cations/
Remarks
Method
Write fi xed value
2995~3117Hz
"513" for each
adjustment point.
[PC test mode]
Transmit at each
Press [Apply All]
adjustment point
button to store the
and check that the
adjustment value
Analog deviation is
after all adjust-
between 2995Hz
ment point was
and 3117Hz.
adjusted.
Deviation meter
LPF: 3kHz
HPF: OFF
[Panel tuning
mode]
PTT: ON
[PC test mode]
PTT: Press [Trans-
mit] button
Write fi xed value
1311~1363Hz
"513" for each
adjustment point.
[PC test mode]
Transmit at each
Press [Apply All]
adjustment point
button to store the
and check that the
adjustment value
Analog deviation is
after all adjust-
between 1331Hz
ment point was
and 1363Hz.
adjusted.
Deviation meter
LPF: 3kHz
HPF: OFF
[Panel tuning
mode]
PTT: ON
[PC test mode]
PTT: Press [Trans-
mit] button