Yunca Gas XANDER INSERT Installation Instructions Manual

Wood burner
Hide thumbs Also See for XANDER INSERT:

Advertisement

BUILT-IN "ZC" INSTALLATIONS
 These instructions cover installations of the Yunca Xander Insert, where the
optional "Zero Clearance Kit" is being used - enabling installation into a
suitably constructed enclosure as per AS/NZS 2918: 2001.
For Masonry, please refer to the separate instruction book.
AUS-Install-Xander_Insert_BUILT-IN_ZC - 2017-08-02.doc
A division of Terry Young Ltd, New Zealand
INSTALLATION INSTRUCTIONS for
XANDER INSERT
WOOD BURNER
HARDWOOD TESTED - AUSTRALIA
26 JUNE 2017
TESTED in compliance with AS/NZS 2918:2001
HARDWOOD TEST No. HCMG/15/088
www.yunca.co.nz
Page 1 of 13

Advertisement

Table of Contents
loading

Summary of Contents for Yunca Gas XANDER INSERT

  • Page 1 TESTED in compliance with AS/NZS 2918:2001 HARDWOOD TEST No. HCMG/15/088  These instructions cover installations of the Yunca Xander Insert, where the optional “Zero Clearance Kit” is being used - enabling installation into a suitably constructed enclosure as per AS/NZS 2918: 2001.
  • Page 2: Safety Information

    SAFETY INFORMATION General:  This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. ...
  • Page 3: Floor Protector

    TESTED in compliance with AS/NZS 2918: 2001 Yunca recommends that competent trades persons carry out all installations (e.g. NZHHA Registered Installer), to obtain maximum performance and safe, efficient heating. A consent is required and we suggest you check with local building inspectors as by-laws do vary from area to area.
  • Page 4: Cavity Dimensions

    Xander Wood Burner Dimensions (Fig. 1)  Dimensions given include the Built-in “Zero Clearance” cabinet and also the bottom infill fascia panel, which is required for ZC installations.  Vented fascia top panel must be used for Built-in (ZC) installations. (The blank fascia top panel is for masonry installations only) Fig.
  • Page 5 YUNCA Insert Flue Kit – Zero Clearance (Complies with AS/NZS 2918:2001): Zero Clearance (Built-in) Flue Kit consists of the following:  4.8m x 150mm stainless steel flue.  4.8m x 200mm galvanised liner.  4.8m x 250mm galvanised liner.  1 x top cap & cowl (cone). ...
  • Page 6 Conditions for Flues (Fig. 4) The FLUE shall extend to:  Not less than 600mm above the highest point on the roof if within 3.0m of that point, or  Not less than 1000mm above the intersection point with the roof and not lower than any point of the roof within 3.0m.
  • Page 7 Xander Built-in (ZC) Installation Thermal Clearances  THERMAL CLEARANCES FRONT VIEW Fig. 5  THERMAL CLEARANCES CROSS SECTION Fig. 6 AUS-Install-Xander_Insert_BUILT-IN_ZC - 2017-08-02.doc www.yunca.co.nz Page 7 of 13...
  • Page 8 Floor Protector Reductions The floor protector extension from the unit can be reduced if the unit is (Fig. 11) elevated. (Table 2) Elevation Increase (mm) Table 2. Floor Protector Reductions for Built-In Installations Built-In (ZC) Xander ZERO CLEARANCE KIT Assembly ...
  • Page 9 Fig. 8 - Zero Clearance Kit ASSEMBLY PROCEDURE AUS-Install-Xander_Insert_BUILT-IN_ZC - 2017-08-02.doc www.yunca.co.nz Page 9 of 13...
  • Page 10 Xander Insert Seismic Fixings Follow local Council’s specifications. Prior to installation, ensure the cavity floor is levelled. Also ensure the mantel face is perpendicular in relationship to the cavity floor. Ensure the unit is securely fixed using sleeve anchors or similar at the locations shown in the images on this page.
  • Page 11: Fan Installation

    Fan Installation (Fig. 11) Take note of the entry and exit points for the cabling, and ensure measures are taken within the cavity to allow for this. Although the fan is controlled automatically by a thermostat it is recommended that an isolator switch is installed in conjunction.
  • Page 12 Xander Wiring Connections Attach the two black thermostat leads to the thermostat terminals. (Fig. 12)  Note: Thermostat is mounted to the underside of the heater in the fan cavity. Attach the thermostat Earth wire to the chassis of the heater. (Fig.
  • Page 13 Fig. 16 Fig. 17 Factory wired fascia circuit box Hard-wired fascia circuit box < END > These instructions, spare parts information, operation and maintenance guides may be downloaded from http://www.yunca.co.nz/installation-operation/ AUS-Install-Xander_Insert_BUILT-IN_ZC - 2017-08-02.doc www.yunca.co.nz Page 13 of 13...

Table of Contents