Bosch CCS 1000 D Operation Manual page 43

Digital discussion system
Hide thumbs Also See for CCS 1000 D:
Table of Contents

Advertisement

Digital Discussion System
Problem
Part of system not working
correctly.
Recording to the internal
memory not possible.
Recording to USB memory
stick not possible.
Bosch Security Systems B.V.
Possible cause
Interrupted system cabling.
Internal memory full.
USB memory stick not fully
inserted in Control Unit.
Incorrect type of USB
memory stick.
USB memory stick incorrectly
formatted.
USB memory stick too large.
USB memory stick full or
damaged.
Operation manual
Troubleshooting | en
Possible solution
Check all trunk
connections between the
Discussion Devices and
the Control Unit.
Check the connections
of the auxiliary
equipment.
Check internal recording
LED indicator: Red/green
flashing indicates that
the internal memory is
full.
Connect a USB cable to
the micro USB connector
at the rear of the Control
Unit and transfer files to
a PC if necessary.
Make sure the USB
memory stick is fully
inserted.
Check that the USB
recording LED indicator
is green: Indicates that
the USB memory stick is
selected and the Control
Unit is ready for
recording.
Use a SanDisk memory stick.
Make sure the USB memory
stick is formatted with the
FAT32 file system.
Do not use a USB memory
stick larger than 128 GB.
Check internal recording
LED indicator: Red/green
flashing indicates that
the internal memory is
full.
Connect the USB
memory stick to a PC,
and transfer the files to a
hard disk if necessary.
Check the read/write
possibilities of USB stick.
2014.09 | V1.0 |
43

Hide quick links:

Advertisement

Table of Contents
loading