Mitsubishi FX1N-2AD-BD User Manual
Mitsubishi FX1N-2AD-BD User Manual

Mitsubishi FX1N-2AD-BD User Manual

Analog input

Advertisement

Quick Links

This manual contains text, diagrams and explanations which will guide the reader in the correct
installation, safe use and operation of the FX
read and understood before attempting to install or use the unit. Further information can be found in the
associated manuals list below.
Specifications are subject to change without notice
Guidelines for the Safety of the User and Protection of the
FX
-2AD-BD Analog Input Expansion Board.
1N
This manual has been written to be used by trained and competent personnel. The definition of such a
person or persons is as follows:
a) Any engineer using the product associated with this manual, should be of a competent nature,
trained and qualified to the local and national standards. These engineers should be fully aware of
all aspects of safety with regards to automated equipment.
b) Any commissioning or service engineer must be of a competent nature, trained and qualified to
the local and national standards.
c) All operators of the completed equipment should be trained to use that product in a safe and
coordinated manner in compliance to established safety practices.
Note: The term 'completed equipment' refers to a third party constructed device which contains or uses
the product associated with this manual.
Note's on the Symbols Used in this Manual
At various times through out this manual certain symbols will be used to highlight points of information
which are intended to ensure the users personal safety and protect the integrity of equipment.
1) Indicates that the identified danger WILL cause physical and property damage.
2) Indicates that the identified danger could POSSIBLY cause physical and property
damage.
Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage
that may arise as a result of the installation or use of this equipment.
All examples and diagrams shown in this manual are intended only as an aid to understanding the
text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the
product based on these illustrative examples.
Owing to the very great variety in possible application of this equipment, you must satisfy yourself as
to its suitability for your specific application.
Associated Manual
Manual Name
FX
Series
1S
Programmable controllers
Hardware Manual
FX
Series
1N
Programmable controllers
Hardware Manual
FX Series of
¤
Programmable controllers
Programming Manual ΙΙ
¤ Indispensable manual
FX
-2AD-BD Analog Input Expansion Board
1N
-2AD-BD Analog Input Expansion Board and should be
1N
Manual
Number
Describes contents related to hardware of the
JY992D83901
FX
1S
and installation.
Describes contents related to hardware of the
JY992D89301
FX
1N
and installation.
Describes instructions in FX
JY992D88101
series.
User's Manual
JY992D96201A
Description
series PLC, such as specifications, wiring
series PLC, such as specifications, wiring
/FX
/FX
/FX
1S
1N
2N
2NC

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi FX1N-2AD-BD

  • Page 1 • All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples.
  • Page 2: System Configuration

    1. Introduction The FX -2AD-BD analog input expansion board (hereafter called “2AD” or “expansion board”) is to be installed in an FX or FX series PLC, to increase the analog input by 2 points. 1.1 Features of 2AD 1) Analog input of two points can be increased using 2AD. If a 2AD is used, internal mounting in the top of the PLC means that there is no need for a change to the installation area of the PLC.
  • Page 3: General Specifications

    2. Specifications 2.1 General Specifications Same as the programmable controller main unit. (Refer to the programmable controller main unit manual) 2.2 Power Supply Specifications Power supplied by internal feed of the programmable controller main unit. 2.3 Performance Specifications Table 2.1: Performance Specifications Specification Item Voltage input...
  • Page 4 4. Wiring Caution: Cut off all phases of power source before installing / removing or performing wiring work on the expansion board in order to avoid electric shock or damage of product. Note: • Do not lay signal cable near to high voltage power cable or house them in the same trunking duct.
  • Page 5: Basic Example Program

    5. Example Program Analog amount (0 ~ 10V, 4 ~ 20mA) input to each channel is stored in data registers (D8112, D8113) as digital values. The values are stored automatically at each END instruction and calculated using the analog to digital conversion characteristic, specified with special auxiliary relays M8112 and M8113. 5.1 Allocated Device Table 5.1: Allocation of Device Device...
  • Page 6 FNC 22 D8113 FNC 20 K4000 Manual number : JY992D96201 Manual revision : A Date : MAY 2001 HEAD OFFICE : MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100-8310 TELEX : J24532 CABLE MELCO TOKYO HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN...
  • Page 7 • Securely install the expansion board, and fix to the PLC. Defective contact can cause text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the • Only one expansion board can be used on one FX and FX PLC main unit.
  • Page 8 *2 For current input, short circuit “V¡+” and “I¡+” as shown in the diagram. Manual number : JY992D96201 Manual revision : A Date : MAY 2001 HEAD OFFICE : MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100-8310 TELEX : J24532 CABLE MELCO TOKYO HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN...