Download Print this page

Honeywell ADEMCO 5821 Installation And Setup Manual page 4

Temperature sensor & flood detector

Advertisement

SPECIFICATIONS
Power: 3V lithium battery
(Duracell DL123A, Panasonic CR123A, Sanyo CR123A,
CR123A, Varta CR123A)
Tekcell
CAUTION:
Risk of fire, explosion, and burns.
recharge,
disassemble,
(100°C) or incinerate. Dispose of used batteries
promptly. Keep away from children.
Operating Temperature:
Operating Voltage:
Dimensions:
Sensor Parameters:
Cold Temperature
(Freeze) Detector
Warm Temperature
Detector
Hot Temperature
Detector
Refrigerator Failure
Detector
Freezer Failure
Detector
✝✝✝
Hysteresis
Flood Sensor
Response Time
✝✝✝✝
Tolerance
Temperature Measurement
Accuracy (internal temp. sensor
or external temp. probe)
✝✝✝ Hysteresis is the temperature difference between "fault" and
"restore" points.
✝✝✝✝ The Response Time Tolerance is the time duration necessary
for the device to respond to a "fault" or "restore" condition. This
time does not take into account the time necessary for the probe
and circuitry to equalize to the ambient temperature. This
feature prevents false alarms due to open doors and other
transitory conditions.
ÊK9947V2}Š
K9947V2 10/05 Rev. A
Do not
heat
above
212°F
14°F (-10°C) to 104°F
(+40°C)
3.2VDC
3.1" length, 1.6"wide, 1.0"
depth
45°F (7°C)
75°F (24°C)
95°F (35°C)
42°F (6°C)
10°F (-12°C)
3°F (-16°C)
¼ inch of water covering
the probe
+50%, -20%
±3°F (-16°C)
165 Eileen Way, Syosset, New York 11791
Copyright © 2004 Honeywell International Inc.
www.honeywell.com/security
TO THE INSTALLER
Regular maintenance and inspection (at least annually) by the installer
and frequent testing by the user are vital to continuous satisfactory
operation of any alarm system.
The installer should assume the responsibility of developing and
offering a regular maintenance program to the user as well as
acquainting the user with the proper operation and limitations of the
alarm system and its components parts. Recommendations must be
included for a specific program of frequent testing (at least weekly) to
ensure the system's proper operation at all times.
FCC ID: CFS8DL5821-1
This device complies with Part 15 of FCC rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
IC: 573F-58211
REFER TO THE INSTALLATION AND SETUP GUIDE FOR THE
CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR
WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE
ALARM SYSTEM.

Advertisement