Download Print this page

Honeywell sixsiren Installation Instructions page 2

Six series

Advertisement

Mounting
NOTE: Before mounting the device permanently,
conduct Go/No Go tests (see controller's
instructions) to verify adequate signal strength and
adjust the device location and orientation as
necessary.
The SiXSIREN can be mounted on the wall or on
the ceiling.
The rear tamper breakout [A] MUST be mounted to
a stud, solid wood, or with a robust wall anchor.
Test the SiXSIREN
The SiXSIREN should be tested immediately after installation and weekly. Activate Test Mode remotely from the
Controller (see Controller's manual for details). The product must be tested at least once a year.
Test Mode tests the sounder and LED:
• Sounder – the Burglary warble tone will sound for 3 seconds.
• LED – the White LED strobe will flash for 15 seconds.
SiXSIREN LEDs and Sounder
Refer to the table below for operation of the four bi-colored LEDs and an 85dB sounder.
LEDs
= ON
R = Red
G = Green
W = White
= Slow Flash
R / W
Red ON for 20
R
seconds
Alternating Red and
White Flashing Strobe
/
R
W
(continues until the
Alarm is cleared)
White Strobe Flashing
W
Red flashes once
R
every 45 seconds
1
Strobe flash = two flashes per second, then OFF for 1 second.
2
It is best to replace the battery BEFORE the chirping begins. Once started, the sounder continues to chirp until batteries are replaced or die. See
the Battery Replacement section.
= Rapid Flash
R
= Strobe Flash
R
G / W
Green Rapid Flashes for
G
G
about 20 seconds, then
Green Slow Flashing for
G
G
Green ON for 20 seconds
1
White Strobe Flashing
W
Green Flashes slowly for
G
[A]
Sounders
= Chirp
= Burglary Warble
ON for 3 seconds
3 seconds
Burglary Warble
ON for 3 seconds
10 minutes
(2)
#6 x 1"
(3.5 mm x 25 mm)
(1)
#4 x 1/4"
(2.9 mm x 6.4 mm)
= Temporal Pulse 3
= Temporal Pulse 4
Sounder
Status
Power Up – Enrollment
Chirps once
Power Up – Device
enrolled
Chirps once
System is Disarmed
System is Armed
Smoke / Heat Alarm
CO Alarm
Burglary Alarm
2
Low Battery
Tamper Activated