Table 2.2 Error Code (Host)
Code
Detail
Cause
80G0A101
-
Sheet information table check error has
occurred.
00040701 Decimal point specification's specification
error
00040801 Barcode recognition specification error
00040802 Barcode recognition count specification
error
00040803 Barcode recognition image specification's
specification error
00040804 Barcode type specification error
00040805 Barcode recognition orientation
specification error
00040810 A non-PP installation error has
occurred.(Code recognition of two
dimensions)
00040850 Patchcode recognition specification error
00040851 Patchcode recognition image
specification's specification error
00040852 Patchcode recognition orientation
specification error
00040853 Order and priority for Patchcode
searching specification error
00040901 Another image using flag specification
error
00040902 Another image using image specification
error
2-26
(15/29)
Recovery
-
Check image setting again
If not recovered, get dump
information (refer to 1.4) and
contact Hitachi.
Check recognition setting
again
Refer to Appendix of this
manual: A-6 Notes on
PatchCode
If not recovered, get dump
information (refer to 1.4) and
contact Hitachi.
Check image setting again
If not recovered, get dump
information (refer to 1.4) and
contact Hitachi.

Advertisement

Table of Contents