<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Perform paper selection for the drawer, key in [98], and then press the [FAX] button to output the
grid pattern (to update the actual value).
(3)
Key in [4732] and press the [START] button.
(4)
Key in [0] and press the [START] button.
(5)
Record the displayed "Reference value (A)" and press the [ENTER] button.
(6)
Key in [4732] and press the [START] button.
(7)
Key in [1] and press the [START] button.
(8)
Record the displayed "actual value (B)" and press the [ENTER] button.
(9)
Calculate the difference between "Reference value (A)" and "actual value (B)" to obtain
"Difference (C)".
Range of difference (C)
C ≤ -10
-10 < C < 10
10 ≤ C
* When the difference between "05-4732-0: Reference value" and "05-4732-1: actual value" is
10 bits, the equipment has already performed automatic correction by approx. 1 mm.
(10) Key in [408] and press the [START] button.
© 2008 - 2011 TOSHIBA TEC CORPORATION All rights reserved
Perform the image location adjustment of the secondary scanning
direction. Proceed to step (10).
The image location of the secondary scanning direction is set
properly. Proceed to step (12).
Perform the image location adjustment of the secondary scanning
direction. Proceed to step (10).