  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS (Always read these precautions before using this equipment.) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. In this manual, the safety precautions are ranked as "DANGER"...
  • Page 4 [DESIGN PRECAUTIONS] DANGER Incorrect operation of the touch switch(s) may lead to a serious accident if the GOT backlight is gone out. When the GOT backlight goes out, the monitor screen turns black, while the input of the touch switch(s) remains active. This may confuse an operator in thinking that the GOT is in "screensaver"...
  • Page 5 [WIRING PRECAUTIONS] DANGER Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions. Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT.
  • Page 6 [STARTUP/MAINTENANCE PRECAUTIONS] DANGER When power is on, do not touch the terminals. Doing so can cause an electric shock or malfunction. Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases. Not switching the power off in all phases can cause a unit failure or malfunction. Undertightening can cause a short circuit or malfunction.
  • Page 7: Revisions

    This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 8: Introduction

    • Since the example indicated by this manual, technical bulletin, the catalog, etc. is reference, please use it after confirming the function and safety of equipment and system when employing. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples.
  • Page 9: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ....................A-1 REVISIONS........................A-5 INTRODUCTION......................A-6 OUTLINE PRECAUTIONS....................A-6 CONTENTS ........................A-7 ABOUT MANUALS .......................A-11 ABBREVIATIONS AND GENERIC TERMS IN THIS MANUAL ........A-12 HOW TO READ THIS MANUAL ...................A-15 1. OVERVIEW............1-1 to 1-5 1.1 Features ........................1-4 1.2 Rough Pre-operation Procedure ................1-5 2.
  • Page 10 6. INSTALLATION............6-1 to 6-6 6.1 Control Panel Inside Dimensions for Mounting GOT..........6-2 6.2 Panel Cutting Dimensions ..................6-3 6.3 Mounting Position .......................6-4 6.4 Control Panel Temperature and Mounting Angle ............6-5 6.5 Installation Procedure....................6-6 7. WIRING..............7-1 to 7-8 7.1 Power Supply Wiring ....................7-2 7.1.1 Cable types and wire end processing .....................7-2 7.1.2 Tools ...............................7-2 7.1.3 Terminal name ..........................7-3...
  • Page 11 11. COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING)....11-1 to 11-10 11.1 Standard I/F Setting ....................11-1 11.1.1 Standard I/F functions......................... 11-1 11.1.2 Standard I/F display operation ....................11-1 11.1.3 Display contents of standard I/F ....................11-2 11.1.4 Installing of communication driver....................11-5 11.2 Data Transfer ......................
  • Page 12 Appendix 1 External Dimensions ................App- 1 Appendix 2 Usage Condition of Utility Function ............App- 4 Appendix 3 List of Functions Added by GT Designer2 Version Upgrade (For GOT1000 Series) ................App- 5 INDEX .................Index-1 A - 10 WWW.NNC.IR...
  • Page 13: About Manuals

    (1D7M25) Describes specifications and settings of the object functions used in GT Designer2 (Sold separately) GOT1000 Series Connection Manual (1/3, 2/3, 3/3) Describes system configurations of the connection method applicable to GOT1000 series and cable creation SH-080532ENG method (1D7M26) (Sold separately) *1 The manual in PDF-format is included in the GT Works2 and GT Designer2 products.
  • Page 14: Abbreviations And Generic Terms In This Manual

    Abbreviation of GT1575-VTBA, GT1575-VTBD GT157 GT1575-VN Abbreviation of GT1575-VNBA, GT1575-VNBD GT1572-VN Abbreviation of GT1572-VNBA, GT1572-VNBD GT1565-V Abbreviation of GT1565-VTBA, GT1565-VTBD GT156 GOT1000 Series GT1562-VN Abbreviation of GT1562-VNBA, GT1562-VNBD GT1555-Q Abbreviation of GT1555-QTBD, GT1555-QSBD GT155 GT1550-Q Abbreviation of GT1550-QLBD GT15 , GT15...
  • Page 15 Abbreviation of screen drawing software GT Designer2 for GOT1000/GOT900 series GT Designer2 Abbreviation of data conversion software GT Converter2 for GOT1000/GOT900 series GT Converter2 Abbreviation of screen simulator GT Simulator 2 for GOT1000 / GOT900 series GT Simulator2 Abbreviation of monitoring software GT SoftGOT1000 GT SoftGOT1000...
  • Page 16 License key (for GT SoftGOT1000) Abbreviations and generic terms Description License GT15-SGTKEY-U, GT15-SGTKEY-P License key (for GT SoftGOT2) Abbreviations and generic terms Description License key A9GTSOFT-LKEY-P (For DOS/V PC) License key FD SW5D5F-SGLKEY-J (For PC CPU module) Others Abbreviations and generic terms Description Omron PLC Abbreviation of PLC manufactured by OMRON Corporation...
  • Page 17: How To Read This Manual

    HOW TO READ THIS MANUAL Functions This manual describes functions available for the GT Designer2 Version2.43V. For the added functions by the product version upgrade, refer to the list of functions added by GT Designer2 version upgrade in Appendices. Symbols Following symbols are used in this manual.
  • Page 18: Overview

    1. OVERVIEW About GOT A GOT is installed on the panel surface of a control panel or operating panel and connects to the PLC within the control panel. The GOT carries out switch operation, lamp display, data display, message display, etc. Connector for program For the display screen, two kinds of screens are available : user screen...
  • Page 19 About Manual The following manuals related to GOT 1000 series are available. Refer to each manual in accordance with the intended use. (1) Installation of the software programs Drawing Data transfer For operations from creating project data to transferring data to GOT, refer to the following manuals.
  • Page 20 The following manuals are also available. The following manuals are stored in the GT Works2/GT Designer2 in PDF format. (a) GOT1000 Series Extended/Option Functions Manual Describes how to use the ladder monitoring function, system monitor function and list editor for MELSEC-A.
  • Page 21: Features

    1.1 Features (1) Improved monitoring performance and connectivity to FA devices • Multiple languages are displayed using the Unicode2.1-compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts • 3 backlight status display colors (green, red, orange) to choose from •...
  • Page 22: Rough Pre-Operation Procedure

    2) Install the project data that were created with GT Designer2 on the GOT. Check the communication settings. Refer to GOT1000 Series Connection Manual. Connect the GOT and the destination connector. Turn on the GOT power and the system of the connection destination.
  • Page 23: System Configuration

    2. SYSTEM CONFIGURATION 2.1 Overall Configuration The overall configuration of GOT is as follows. For the connection methods applicable to GOT1000 series and cable, refer to the following. GOT1000 Series Connection Manual Protective sheet Personal computer RS-232 cable (designed exclusively for use with the GOT)
  • Page 24: Component List

    2.2 Component List (1) Explanation of the GOT model name G T 1 0 2 0 Interface type : RS-232 for communication with PLC Blank : RS-422 Power type : 100 to 240VAC : 24VDC : 5VDC Panel color type B : Black T : TFT color (High intensity, wide angle view) Display device type...
  • Page 25: Got (Gt10)

    2.2.1 GOT (GT10) Product name Model name Specifications " [160 64 dots], STN monochrome (black and white) liquid crystal, GT1020-LBD 3 colors (green/red/orange) LED backlight, 24VDC, PLC connection interface: RS-422 " [160 64 dots], STN monochrome (black and white) liquid crystal, GT1020-LBD2 3 colors (green/red/orange) LED backlight, 24VDC, PLC connection interface: RS-232...
  • Page 26 For connecting PC (drawing software) (USB) cable and RS-232/USB conversion adaptor Connector shape on the cable is shown in ( ). GT09-C30USB-5P is a product of Mitsubishi Electric System Service. Cable for multiple GOT connections (Sold separately) Product name Model name...
  • Page 27: Specifications

    3. SPECIFICATIONS 3.1 General Specifications Item Specifications Display section 0 to 50 Operating ambient Other than 0 to 55 (when horizontally installed), 0 to 50 (when vertically installed) temperature display section Storage ambient temperature -20 to 60 10 to 90% RH, non-condensing Operating ambient humidity 10 to 90% RH, non-condensing Storage ambient humidity...
  • Page 28: Performance Specifications

    3.2 Performance Specifications Specifications Item GT1020-LBD GT1020-LBD2 GT1020-LBL Type STN monochrome (white/black) liquid crystal Screen size 3.7" Resolution 64 dots (Horizontal format) Display size W86.4(3.4) H34.5(1.35) [mm](inch) (Horizontal format) Display character 16-dot standard font: 20 characters 4 lines (Horizontal format) Display Display color Monochrome (white/black)
  • Page 29: Power Supply Specifications

    3.3 Power Supply Specifications Specifications Item GT1020-LBD GT1020-LBD2 GT1020-LBL 5VDC (±5%), supplied from Input power supply voltage 24VDC (+10% -15%), ripple voltage 200mV or less the PLC Fuse (built-in, not − 0.4A exchangeable) Power consumption 1.9W (80mA/24VDC) or less 1.1W (220mA/5VDC) or less At backlight off 1.2W (50mA/24VDC) or less 0.6W (120mA/5VDC) or less...
  • Page 30: Part Name

    4. PART NAME 4.1 Front Panel MITSUBISHI 1000 1) 2) Name Specifications Displays the utility screen and the user creation screen. Display screen 64 dots, STN monochrome (white/black) liquid crystal Touch key For operating the touch switches in the utility screen and the user creation screen 4 - 1 4.1 Front Panel...
  • Page 31: Back Panel

    4.2 Back Panel 4.2.1 GT1020-LBD INPUT 24VDC (FG) RS-422 RS-232 Name Specifications 1) PLC connection interface (RS-422) For connection to a controller (PLC) (9-pin connector terminal block) 2) Power terminal 24VDC (+10% -15%) For PC connection (OS installation, Project data, download, transparent) 3) PC connection interface (RS-232) (MINI-DIN 6 pins, female) −...
  • Page 32: Gt1020-Lbd2

    4.2.2 GT1020-LBD2 INPUT 24VDC (FG) RS-232 RS-232 Name Specifications 1) PLC connection interface (RS-232) For connection to a controller (PLC) (9-pin connector terminal block) 2) Power terminal 24VDC (+10% -15%) For PC connection (OS installation, Project data, download, transparent) 3) PC connection interface (RS-232) (MINI-DIN 6 pins, female) −...
  • Page 33: Gt1020-Lbl

    4.2.3 GT1020-LBL RS-232 -- INPUT + 5VDC Name Specifications 1) PLC connection interface (RS-422) For connection to a controller (PLC) (9-pin connector terminal block) For PC connection (OS installation, Project data download, transparent) 2) PC connection interface (RS-232) (MINI-DIN 6 pins, female) −...
  • Page 34: Emc Directive

    - Equipment, requirement and tests (ESD,RF electromagnetic field, EFTB, Surge, RF conducted disturbances and Power frequency magnetic field) For more details please contact the local Mitsubishi Electric sales site. 5 - 1 5.1 Requirements for Conformance to EMC Directive 5.1.1 Standards applicable to the EMC Directive...
  • Page 35: About Models Applicable To The Emc Directive

    GRAPHIC OPERATION TERMINAL GT1020-LBD MODEL IN 20.4 26.4VDC POWER 1.9W MAX SERIAL 6Y0001 AB Hardware version MITSUBISHI ELECTRIC CORPORATION MADE IN JAPAN JY204D42501C 80M1 IND. CONT. EQ US LISTED 5.1.3 About the cable used General notes on the use of communication cables Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise.
  • Page 36: Installation

    6. INSTALLATION DANGER MOUNTING PRECAUTIONS Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to/from the panel. Not doing so can cause the unit to fail or malfunction. CAUTION MOUNTING PRECAUTIONS Use the GOT in the environment that satisfies the general specifications described in this manual.
  • Page 37: Control Panel Inside Dimensions For Mounting Got

    6.1 Control Panel Inside Dimensions for Mounting Mount the GOT onto the control panel while considering the following control panel inside dimensions. Horizontal format 23(0.9") 80(3.14") or more 104(4.09") (0.15") (0.37") Mounting (0.39") (0.39") 3(0.11") 76(2.99") fixtures INPUT 24VDC (FG) RS-422 RS-232 RS-232 cable...
  • Page 38: Panel Cutting Dimensions

    6.2 Panel Cutting Dimensions Cut holes in the following dimensions on the panel. A space of at least 13 mm (0.51”) at the top and bottom is required to allow for the attachment of mounting fixtures. Horizontal format +0.03 (4.13" −0 −0 Unit: mm(inch)
  • Page 39: Mounting Position

    GOT units. 50 mm (1.97”) or more if an RS-232/USB conversion adaptor is used and is connected to the RS-232 interface for PC. Other device or control panel MITSUBISHI 1000 Vertical format Installation Environment In the presence of radiated-noise or 50 mm (1.97”)
  • Page 40: Control Panel Temperature And Mounting Angle

    6.4 Control Panel Temperature and Mounting Angle When mounting the main unit to a control panel or similar fixture, set the GOT display section as shown below. Horizontal installation When the temperature inside the control panel is 40 to 55 , the mounting angle should be in the range from 60 to 105 degrees.
  • Page 41: Installation Procedure

    6.5 Installation Procedure The GOT is designed to be embedded into a panel. Mount the GOT by following the procedure below. For panel cutting dimensions, refer to Section 6.2. Note that the panel thickness should be within 1 to 4mm. Installing the packing Packing Install packing to the packing installation groove on...
  • Page 42: Wiring

    Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit. This chapter describes the wiring to the GOT power supply section. (1) For the connection with a PLC, refer to the following. GOT1000 Series Connection Manual Remark General preventive measures against noise There are two kinds of noises: Radiated noise that is transmitted into the air and Conductive noise that is directly transmitted along connected lines.
  • Page 43: Power Supply Wiring

    7.1 Power Supply Wiring Connect the power supply to the power terminals on the back panel of the GOT. Use a specified size power supply wire to prevent voltage drop, and tighten the terminal screws firmly to a specified torque. Do not exceed the number of wires that are allowed to be connected.
  • Page 44: Terminal Name

    7.1.3 Terminal name INPUT 24VDC INPUT 24VDC (FG) (FG) RS-422 RS-422 RS-232 7.1.4 Power supply wiring Power terminals on the GOT +10% DC24 -15% INPUT 24VDC (FG) Class D grounding Tightening torque for the power terminals 0.22 to 0.25 N•m Grounding the GOT and other devices Make sure to carry out the followings for grounding.
  • Page 45 Recommended terminal shape Terminal Solderless Terminal Solderless screw terminal 3.2 (0.12") screw terminal 6.2mm (0.24") or less 3.2 (0.12") 6.2mm (0.24") or less When wiring one cable to When wiring two cables to one terminal one terminal Cable size For power supply: 0.75mm min.
  • Page 46: The Cause Of Malfunctions Related Wiring/Remedy

    Bundling the GOT's ground cable and power line together can cause interference noise, which may result in malfunctions. Keeping the GOT's ground cable and power line away from each other will help minimize noise interference. MITSUBISHI MITSUBISHI 1000 1000 Power supply for power equipment...
  • Page 47 If the electric potential difference between the ground cable and the panel that houses the GOT is creating problems, connect the ground cable to the panel also. If the wiring method as shown in Remedy 1-1 is not feasible, follow Remedy 1-2. MITSUBISHI MITSUBISHI Connection cable...
  • Page 48: Wiring Inside And Outside The Panel

    7.2 Wiring inside and outside the panel 7.2.1 Wiring inside Run power lines, servo amplifier drive wires, and communication cables so that they do not cross each other. Noise interference that is generated by cables that cross each other may cause malfunctions. Surge suppressors are an effective way to filter out surge noise that is generated from no fuse breakers (NFB), electromagnetic contactors (MC), relays (RA), solenoid valves, and induction motors.
  • Page 49: Attaching Surge Killers To Control Equipment

    7.2.3 Attaching surge killers to control equipment If communication errors happen in synch with the on/off signals from certain control equipment (referred to as "load" hereafter) such as no fuse breakers, electromagnetic contactors, relays, solenoid valves, and induction motors, surge noise interference is suspected. If this problem happens, keep the ground cable and communication cable away from the load.
  • Page 50: Protective Sheet

    8. OPTION 8.1 Protective Sheet The protective sheet is used to protect the operation surface from damage or dirt when the touch key of GOT display section is operated. 8.1.1 Applicable protective sheet The following protective sheets are applicable for GT10 Product name Model Contents...
  • Page 51: Installing Procedure

    8.1.2 Installing procedure If a protective sheet is on the GOT, peel off the protective sheet from the bottom-right corner of the GOT display section, and clean the GOT surface. Peel the release paper from the back of the new protective sheet, and attach its adhesive side to the GOT display section.
  • Page 52: Rs-232/Usb Conversion Adaptor

    Personal computer Installing port USB cable for connecting a personal computer (Mitsubishi Electric System Service Co, LTD) Conversion adaptor 8.2.1 Shape, Dimensions, and Names of Adaptor Components The shape, dimensions, and names of the RS-232/USB conversion adaptor are shown in the figures below.
  • Page 53: Installing Procedure

    8.2.2 Installing procedure Turn off the GOT power. Connect the USB mini connector on the GT09-C30USB-5P USB cable to the RS-232/USB conversion adaptor. Connect the RS-232 connector on the RS-232/USB conversion adaptor to the GOT. Connect the USB connector on the GT09-C30USB-5P USB cable to the PC. Turn on the GOT power.
  • Page 54: Driver Installation

    8.2.3 Driver installation Procedure for installing the driver is explained below. Windows XP installation follows. • Windows 98, Windows 98SE, Windows Millennium Edition, and Windows 2000, the installation method will vary. Installation of the driver is canceled during the following process, the installation is not carried out correctly. If the installation is canceled, uninstall the driver and install again.
  • Page 55 The following screen is displayed. Click [ Finish ]. The installation of the USB driver software will finish. • If Windows 98, Windows 98SE or Windows Millennium Edition is used, installation of the USB Serial Port software begins, and ends automatically. The CD-ROM can be removed from the personal computer at this time.
  • Page 56 The following screen is displayed. Click [ Finish ]. The installation of the USB Serial Port software will finish. The CD-ROM (USB driver software) can be removed from the personal computer at this time. 8 - 7 8.2 RS-232/USB conversion adaptor 8.2.3 Driver installation WWW.NNC.IR...
  • Page 57: Method For Uninstalling Driver

    8.2.4 Method for Uninstalling Driver The procedure for uninstalling the driver is explained below. A Windows XP example follows. When the driver softwares for FX-USB-AW/FX -USB-BD and GT10-RS2TUSB-5S are installed, uninstalling one of these driver softwares may cause the other not to function properly.
  • Page 58: Utility Function

    9. UTILITY FUNCTION The utility functions allow the user to confirm the settings for communication interface, screen display, operation methods, and clock data as well as OS information. GT10 is factory-installed with the Standard monitor OS and BootOS. (An installation of the Standard monitor OS or BootOS is not required to use the utility functions.) 9.1 Utility Function List The items in the following list can be set/operated on the utility screens.
  • Page 59: Utility Display

    9.2 Utility Display 9.2.1 Display operation of main menu The following three types of operation can display the main menu. (The utility function windows appear in the horizontal format, and this format cannot be changed.) (1) When project data is undownloaded After the GOT is turned on, a dialog box for notifying of absence of project data is displayed.
  • Page 60 Remark Lock the utility display by password. When a password is set on the GOT using GT Designer2, a password dialog box is displayed when trying to access the main menu of the utility display. (The password setting option in GT Designer2 is located in the common menu.) Enter the password that has been set.
  • Page 61: Utility Basic Configuration

    9.2.2 Utility basic configuration The basic configuration of the screen is as follows. Main Menu The menu items that can be selected from the GOT utility are displayed. Use the buttons to select an item from the menu. Touching a menu item in the main menu will display the setting screen or following selection screen for the item.
  • Page 62: Language Setting (Language)

    10. LANGUAGE SETTING (Language) 10.1 Display language setting 10.1.1 Display language setting function This function allows display language selection. The items which can be set are shown below. Item Contents Setting range Display language in which the utility functions and dialog windows Japanese/English Language are displayed can be selected or confirmed in this menu...
  • Page 63: Communication Interface Setting (Communication Setting)

    11. COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING) The [Communication Setting] menu has the [Standard I/F], [Data Transfer], and [Communication Monitor] menus. The [Standard I/F] menu displays the information about the channel numbers, controller name, and detailed settings of the communication parameters that are allocated to the communication interfaces by GT Designer2.
  • Page 64: Display Contents Of Standard I/F

    11.1.3 Display contents of standard I/F Described below are the display items on the standard I/F setting menu and their functions. Display item column Communication interface selection button Standard interface display BOX Driver display BOX Channel no. display BOX (1) Communication interface selection button Select the communication interface to be displayed.
  • Page 65 (3) Channel no. display BOX Set when the communication interface is not used. Set when connecting to PLC. (settable only for the interface (Standard I/F-1) for communication with PLC) Set when connecting to PC (GT Designer2). • Setting is not allowed for 2 to 8, *. (4) Driver display BOX The name of the communication driver for which a channel number is assigned is displayed.
  • Page 66 Precautions for communication between GOT and connected devices (1) Installing [Communication driver] and downloading [Communication Settings] To perform communication with the connected device, the following actions are necessary. 1) Installing [Communication driver] (Up to 1, OS installation) The driver for [MELSEC-FX] is factory-installed. Install the communication driver to connect a controller other than a MELSEC-FX.
  • Page 67: Installing Of Communication Driver

    11.1.4 Installing of communication driver GT10 is factory-installed with the driver for MELSEC-FX. An installation of the communication driver is required when connected to a controller other than a MELSEC-FX. When installing communication driver onto the GOT, power on the GOT in the OS transmission mode. (Operating of transmission mode) Turn the GOT power on with the lower right...
  • Page 68: Data Transfer

    11.2 Data Transfer 11.2.1 Data transfer functions Function Contents Displays the screen for transferring project data between the PC and GOT. If any device other than the PC is allocated to the interface for communication Data transfer screen display with PC, the GOT will not be able to communicate with the PC, except when the Data transfer window is on the screen.
  • Page 69: Data Transfer Display

    11.2.3 Data transfer display [Waiting] on the data transfer screen will change to [Transferring...] when project data are transferred from GT Designer2. At the completion of data transfer, the user-created screen will appear. Transfer of project data from GT Designer2 Completion of data transfer User-created screen 11.2 Data Transfer...
  • Page 70: Communication Monitor

    11.3 Communication Monitor 11.3.1 Communication Monitor functions Function Contents Communication port-selection Displays the connection status of Standard I/F-1 and I/F-2 status display Communication status display Displays the communication status (SD: send, RD: receive) Communication error status display Displays an error message when a communication error occurs 11.3.2 Communication Monitor display operation Main Menu Touch...
  • Page 71: Screen Display Content

    11.3.3 Screen display content Connection status of the communication ports Indicates the connection status of Standard I/F-1 and I/F-2. Listed in the table below are display items and the connection status (channel number). Display item Channel number Remarks "PLC" appears when connected to a controller (PLC or microcomputer) "TRANS."...
  • Page 72 Communication error status Communication error status of each port is displayed on this screen. The table below summarizes the types and nature of the errors. Display item Action NO ERROR Communication is executed normally. The receive data is sent continuously with a short interval. ERR Ovr.
  • Page 73: Display And Operation Settings (Got Set Up)

    12. DISPLAY AND OPERATION SETTINGS (GOT SET UP) Setting screen for display and setting screen for operation can be displayed from GOT setup. In the setting screen for display and the setting screen for operation, the following settings can be set. Screen Description Screen save time...
  • Page 74: Display Operation Of Display Setting

    12.1.2 Display operation of display setting Main Menu Touch Touch [GOT setup]. Display GOT setup Touch [Display]. 12 - 2 12.1 Display Settings 12.1.2 Display operation of display setting WWW.NNC.IR...
  • Page 75: Display Setting Operations

    12.1.3 Display setting operations Screen save time Display Touch [Screen Save] to bring up the screensaver setting window. Touch [Screen save]. Touch [Time] to bring up the time setting window. Touch [Time]. Touch the time that appears on the time setting window to bring up the ten-key pad.
  • Page 76 Screen save backlight Display Touch [Screen Save] to bring up the screensaver setting window. Touch [Screen save]. Touch [Backlight] to bring up the backlight setting window. Touch [Backlight]. Touch the button to turn off/turn on the backlight. • button: Screen save, Transferring..., Backlight, Unlit •...
  • Page 77 Contrast Display Touch [Contrast] to bring up the setting window. Touch [Contrast]. Touch the [−] and [+] buttons to adjust the contrast of the screen. Adjust contrast with the [−] and [+] buttons. After changing the settings, touch the button to save the changes and close the setting Touch window.
  • Page 78: Operation Settings

    12.2 Operation Settings 12.2.1 Operation setting functions Setting regarding GOT operation can be set. The items which can be set are described below. Function Contents Setting range OFF/SHORT/LONG Buzzer volume Buzzer volume setting can be changed <At factory shipment: SHORT> −...
  • Page 79: Setting Operation Of Operation

    12.2.3 Setting operation of operation Buzzer volume Operation Touch [Buzzer volume] to bring up the setting screen. Touch [Buzzer volume]. Touch a setting item to change the setting. (Buzzer volume: SHORT LONG Touch After changing the settings, touch the button to save the changes and close the setting Touch window.
  • Page 80 Calibration Operation Touch [Calibration] to bring up the setting screen. Touch [Calibration]. Touch the "+" symbol at the top left corner. Touch Touch the "+" symbol at the bottom left corner. Touch Touch the "+" symbol at the top right corner. Touch Touch the "+"...
  • Page 81 Touch panel calibration error If touch panel calibration results in inoperability of the panel, the following message will appear. button: Returns to the touch panel calibration screen. button: Aborts calibration without saving any changes to the touch panel setting. 12.2 Operation Settings 12 - 9 12.2.3 Setting operation of operation WWW.NNC.IR...
  • Page 82: Clock Setting (Time Setting And Display)

    13. CLOCK SETTING (TIME SETTING AND DISPLAY) The clock data (date and time) are made in the clock setting menu. 13.1 Time Setting and Display 13.1.1 Time setting and display functions Function Contents Clock display Displays and sets up PLC CPU clock data 13.1.2 Clock display and setting operation Main Menu Touch...
  • Page 83: Clock Setting Operations

    13.1.3 Clock setting operations Clock display Displays and sets up the clock data on the GOT. Touch either the date or time to be changed. Touch the item to be changed. Enter date or time on the ten-key pad. The day of the week is displayed automatically according to the input date.
  • Page 84: File Display (Data)

    14. FILE DISPLAY (DATA) This function displays the version of the OS (Standard monitor OS, BootOS) and communication driver that are written to the GOT. Project data and resource data can be deleted with this function. 14.1 Data Storage Location The following drive name (C drive) is assigned to the built-in Flash Memory on the GT1020.
  • Page 85: Os Information Operation

    14.2.3 OS information operation OS information display Touch the buttons to toggle through the version of the [Standard monitor OS], [Communication driver], and [BootOS]. Touch the button to close the screen. 14.2 OS Information 14 - 2 14.2.3 OS information operation WWW.NNC.IR...
  • Page 86: Clear Data

    14.3 Clear data 14.3.1 Clear data functions This function deletes the project data and resource data that are written to the GOT. 14.3.2 Clear data display Main Menu Touch [Data]. Touch Clear data Data Touch [Clear data]. 14.3.3 Clear data operation Touch the type of data on the screen to be deleted.
  • Page 87: Os Installation

    15. OS INSTALLATION 15.1 About the OS GT10 is factory-installed with the BootOS, Standard monitor OS, and communication driver ([MELSEC-FX]). Standard monitor OS is upgradeable from GT Designer2. An installation of the communication driver is required when connected to a controller other than a MELSEC-FX. (BootOS cannot be installed from GT Designer2.) 15.2 Standard monitor OS/ Communication Driver Installation...
  • Page 88 At the completion of Standard monitor OS/ communication driver installation, the GOT reboots itself and the user-created screen will appear. If no project data exist, a dialog will appear indicating that no project data exist. Checking the communication driver version Some versions of the Standard monitor OS and communication driver may not be compatible with each other, and the communication driver may not function properly.
  • Page 89: Maintenance And Inspection

    16. MAINTENANCE AND INSPECTION STARTUP AND MAINTENANCE DANGER PRECAUTIONS When power is on, do not touch the terminals. Doing so can cause an electric shock or malfunction. Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases.
  • Page 90: Daily Inspection

    16.1 Daily Inspection Daily inspection items Inspection Inspection Item Criterion Action Method Check for loose Retighten screws within the GOT mounting status Securely mounted mounting screws. specified torque range Retighten screws Loose terminal screws Not loose Retighten terminal screws with screwdriver Connection status Retighten connector fixing...
  • Page 91: Cleaning Method

    16.3 Cleaning Method Use the GOT always in a clean condition. To clean the GOT, wipe the dirty part with a soft cloth using neutral detergent. Precautions for cleaning Do not use chemicals such as thinner, organic solvents and strong acids, since they may cause the protective sheet to be deformed or the dissolvable paint on the surface to peel off.
  • Page 92: Appendices

    APPENDICES Appendix 1 External Dimensions External dimensions of GT10 113(4.44") (0.19") 80(3.14") or more (0.39") (0.39") 76(2.99") (0.29") MITSUBISHI 1000 76(2.99") Panel thickness: 1 to 4mm (0.37") (0.39") (0.39") (0.03" to 0.15") Unit: mm(inch) App - 1 Appendix 1 External Dimensions...
  • Page 93 External dimensions of communication cable GT10-C R4-8P 30(1.18") 40(1.57") 250(9.84") φ13(0.51") φ7(0.27") φ25 Unit: mm(inch) 33(0.98" 1.29") Model name L (mm (inch)) Remarks GT10-C10R4-8P 1,000 (39.37") GT10-C30R4-8P 3,000 (118.11") RS-422 cable for direct connection to FXCPU (8-pin MINI-DIN) GT10-C100R4-8P 10,000 (393.7") GT10-C R4-25P 30(1.18")
  • Page 94 External dimensions of RS-232/USB conversion adaptor GT10-RS2TUSB-5S 40(1.57") 200(7.87") 75(2.95") Unit : mm(inch) Weight : Approx. 40g App - 3 Appendix 1 External Dimensions WWW.NNC.IR...
  • Page 95: Appendix 2 Usage Condition Of Utility Function

    Appendix 2 Usage Condition of Utility Function Different functions are available on the GOT and drawing software. : Applicable : N/A GT10 Drawing Setting Setting items Function (Utility) (GT Designer2) Language Message language switching (Japanese/English) Displays the channel number and communication driver that are allocated to the communication interface Standard I/F Communication parameter display...
  • Page 96: Appendix 3 List Of Functions Added By Gt Designer2 Version Upgrade (For Got1000 Series)

    Appendix 3 List of Functions Added by GT Designer2 Version Upgrade (For GOT1000 Series) Appendix 3.1 GT10 GT10 is supported by GT Designer2 Version 2.43V and later. Added GOT main unit Target models Version of GT Designer2 Version of OS GT1020-LBD, GT1020-LBD2, GT1020-LBL 2.43V...
  • Page 97: Index

    INDEX Performance specifications ........ 3-2 Power supply specifications ....... 3-3 ............12-7 Buzzer volume ........14-1,15-1 Standard monitor OS ..........2-1 System configuration ........... 16-3 Cleaning of display ............13-1 Clock setting ........... 13-1 Time setting and display ..........11-8 Communication monitor ........
  • Page 98 Index-2 WWW.NNC.IR...
  • Page 99 1. Gratis Warranty Term and Gratis Warranty Range If any faults or defects (hereinafter "Failure") found to be the responsibility of Mitsubishi occurs during use of the product within the gratis warranty term, the product shall be repaired at no cost via the sales representative or Mitsubishi Service Company.
  • Page 100 Microsoft Windows, Windows NT are registered trademarks of Microsoft Corporation in the United States and other countries. Ethernet is a trademark of Xerox Co., Ltd. in the United States. Other company and product names herein may be either trademarks or registered trademarks of their respective owners. WWW.NNC.IR...