3-2.

SYSTEM CONTROL SYSTEM ADJUSTMENT

1. Initialization of D, E, F, 7 Page Data

If the D, E, F, 7 page data is erased due to some reason, perform "1-
2. INITIALIZATION OF D, E, F, 7 PAGE DATA", of "5-1.
CAMERA SECTION ADJUSTMENT"
3-3.

SERVO SYSTEM ADJUSTMENTS

1. CAP FG Offset Adjustment (VC-234 board)

Improve the capstan servo characteristic. If it is not correct. jitters
will increase.
Mode
Camera recording (SP mode)
Subject
Arbitrary
Measurement Point
Pin qs of CN982 (CAP FG)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
64
Specified value
Duty = 50 ± 1 %
Adjusting method:
1)
Set to the Camera recording mode (SP mode).
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 6, address: 01, set data: 81, and press the PAUSE
button of the adjustment remote commander. (to start up
automatic CAP FG offset adjustment.)
4)
Select page: 6, address: 02, and check that the data is "01".
5)
Check that Duty of CAP FG signal satisfies the specified value.
If not, select page: 6, address: 01, set data: 00, and press the
PAUSE button, and then, repeat steps 1) to 5).
6)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 0, address: 01, and set data: 00.
Center of movement
A
B
Fig. 5-3-4.
Duty = A/B × 100 [%]

2. Switching Position Adjustment (VC-234 board)

If deviated in this case causes switching noise or jitter on the played
back screen.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 22, set data: C0, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 62, change the data and minimize "t1",
and then press the PAUSE button of the adjustment remote
commander. (Coarse adjustment)
4)
Select page: F, address: 63, change the data and adjust so that
the switching position (t1) becomes the specified value. (Fine
adjustment)
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: F, address: 22, set data: 80, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 0, address: 01, and set data: 00.
CH1
CH2
Enlargement
CH1
CH2
5-39
Playback
Alignment tape:
For tracking adjustment
(WR5-1CP)
CH1: Pin qa of CN982 (RF SWP)
CH2: Pin 6 of CN982 (PB RF)
Oscilloscope
F
62, 63
t1 = 0 ± 10 µsec
t1=0 ± 10 µ sec
Fig. 5-3-5.