Cisco Catalyst 2360 Hardware Installation Manual
Cisco Catalyst 2360 Hardware Installation Manual

Cisco Catalyst 2360 Hardware Installation Manual

Hide thumbs Also See for Catalyst 2360:
Table of Contents

Advertisement

Quick Links

Catalyst 2360 Switch
Hardware Installation Guide
December 2010
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Text Part Number: OL-22150-02

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Catalyst 2360

  • Page 1 Catalyst 2360 Switch Hardware Installation Guide December 2010 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Text Part Number: OL-22150-02...
  • Page 2 You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures: •...
  • Page 3: Table Of Contents

    USB Mini-Type B Port Power-Supply Modules Fan Module Management Options 1-10 Network Configurations 1-11 Switch Installation C H A P T E R Preparing Safety Warnings Installation Guidelines Box Contents Tools and Equipment Verifying Switch Operation Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 4 Diagnosing Problems Switch POST Results Switch LEDs Switch Connections Bad or Damaged Cable Ethernet and Fiber-Optic Cables Link Status 10/100/1000 Port Connections SFP and SFP+ Module Interface Settings Ping End Device Spanning Tree Loops Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 5 Installing the Cisco Microsoft Windows XP USB Driver Installing the Cisco Microsoft Windows 2000 USB Driver Installing the Cisco Microsoft Windows Vista and Windows 7 USB Driver Uninstalling the Cisco Microsoft Windows USB Driver Uninstalling the Cisco Microsoft Windows XP and 2000 USB Driver...
  • Page 6 Contents Entering the Initial Configuration Information IP Settings Completing the Setup Program N D E X Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 7: Preface

    SAVE THESE INSTRUCTIONS The safety warnings for this product are translated into several languages in the Regulatory Compliance and Safety Information for the Catalyst 2360 Switch. The EMC regulatory statements are also included in that guide. Catalyst 2360 Switch Hardware Installation Guide...
  • Page 8: Related Publications

    Obtaining Documentation and Submitting a Service Request For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html...
  • Page 9: Chapter 1 Product Overview

    C H A P T E R Product Overview The Catalyst 2360 switch, also referred to as the switch, is an Ethernet switch to which you can connect devices such as servers, routers, and other switches. Switch Description, page 1-1 •...
  • Page 10: 10/100/1000 Ports

    Category 6 unshielded twisted pair (UTP) cable. The 10BASE-T traffic can use Category 3 or Category 4 UTP cable. For information about port connections and port specifications, see the “10/100/1000 Port Connections” section on page 2-11 Appendix B, “Connector and Cable Specifications.” Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 11: Sfp And Sfp+ Module Slots

    10GBASE-USR SFP+ Module For information about SFP modules, see the SFP module documentation and the “Installing SFP and SFP+ Modules” section on page 2-8. For cable specifications, see Appendix B, “Connector and Cable Specifications.” Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 12: Usb Mini-Type B Port

    S P E D M O D E 12 X 14 X System LED Duplex LED Power supply 1 LED Speed LED Power supply 2 LED Mode button Fan LED Port LEDs Status LED Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 13: System Led

    Each port and module slot has a port LED. As a group or individually, the LEDs show information about the switch and about the ports. Table 1-7 lists the mode LEDs and the associated port modes and meanings. Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 14 SFP and SFP+ module ports Port is not operating. Blinking green Port is operating at up to 10 Gb/s with an SFP+ module installed. Green Port is operating at 1 Gb/s with an SFP module installed. Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 15: Rear Panel

    The interface supports Cisco USB flash drives with capacities from 64 MB to 1 GB. Cisco IOS software provides standard file system access to the flash device: read, write, erase, and copy, as well as formatting of the flash device with a FAT file system.
  • Page 16: Ethernet Management Port

    You can disable USB console operation by using Cisco IOS commands. See the switch software configuration guide for details. If you use the USB console port, the Cisco Windows USB device driver must be installed on any PC connected to the console port (for operation with Microsoft Windows).
  • Page 17: Power-Supply Modules

    Power-Supply Modules The Catalyst 2360 switch is powered by two 135 W power-supply modules. The Catalyst 2360 power-supply module is an autoranging unit that supports input voltages from 100–240 VAC. The AC-power-supply module uses an 18-AWG power cord for connection to an AC power outlet.
  • Page 18: Management Options

    Cisco Network Assistant is a PC-based network management GUI application for LANs of small and medium-sized businesses. You can use the GUI to configure and manage switch clusters or standalone switches. Cisco Network Assistant is available at no cost and can be downloaded from this URL: http://www.cisco.com/go/networkassistant...
  • Page 19: Network Configurations

    HP OpenView or SunNet Manager. The switch supports a comprehensive set of Management Information Base (MIB) extensions and four Remote Monitoring (RMON) groups. See the switch software configuration guide on Cisco.com and the documentation that came with your SNMP application for information.
  • Page 20 Chapter 1 Product Overview Management Options Catalyst 2360 Switch Hardware Installation Guide 1-12 OL-22150-02...
  • Page 21 Safety Warnings Read this section before you start the installation procedure. Translations of the warning statements appear in the Regulatory Compliance and Safety Information for the Catalyst 2360 Switch guide on the documentation CD and online at Cisco.com. To prevent the switch from overheating, do not operate it in an area that exceeds the maximum Warning recommended ambient temperature of 113•F (45•C).
  • Page 22: Chapter 2 Switch Installation

    Statement 1040 Warning For connections outside the building where the equipment is installed, the following ports must be connected through an approved network termination unit with integral circuit protection: 10/100/1000 Ethernet. Statement 1044 Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 23: Installation Guidelines

    Box Contents The switch getting started guide describes the box contents. If any item is missing or damaged, contact your Cisco representative or reseller for support. Tools and Equipment You need to supply a number-2 Phillips screwdriver.
  • Page 24: Verifying Switch Operation

    LEDs reflect the status of the corresponding module. If a switch fails POST, the System LED turns amber. POST failures are usually fatal. Call Cisco technical support representative if your switch fails POST. After a successful POST, unplug the power cord from the switch. Install the switch in a rack as described in the “Installing the Switch”...
  • Page 25: Attaching The Rack-Mount Brackets

    Installing the Switch Figure 2-1 Rack-Mounting Brackets 19 inch ETSI Attaching the Rack-Mount Brackets Use three Phillips flat-head screws to attach the long side of the bracket to each side of the switch (Figure 2-2). Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 26 10 0-2 40 PW R OK 10 0-2 40 PW R OK 1.5 -0. 75 50 -60 Hz 1.5 -0. 75 50 -60 Hz Front-mounting position Mid-mounting position Number-8 Phillips flat-head screws Rear-mounting position Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 27: Mounting In A Rack

    Number-12 Phillips machine screws Phillips machine screw, black Mid-mounting position Front-mounting position Rear-mounting position When you complete the switch installation, see the “After Switch Installation” section on page 2-8 information on switch configuration. Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 28: After Switch Installation

    “SFP and SFP+ Module Slots” section on page 1-3 and the switch release notes on Cisco.com for the list of supported SFP modules. Use only Cisco SFP modules on the switch. For information about installing, removing, cabling, and troubleshooting SFP modules, see the module documentation that shipped with your device.
  • Page 29: Removing An Sfp Or Sfp+ Module

    Do not remove the rubber plugs from the SFP or SFP+ module port or the rubber caps from the Caution fiber-optic cable until you are ready to connect the cable. The plugs and caps protect the SFP module ports and cables from contamination and ambient light. Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 30: Connecting To 1000Base-T Sfp

    When connecting to switches or repeaters, use a four twisted-pair, crossover cable. When connecting to a 1000BASE-T device, be sure to use a four twisted-pair, Category 5 or higher cable. Catalyst 2360 Switch Hardware Installation Guide 2-10 OL-22150-02...
  • Page 31: 10/100/1000 Port Connections

    The automatic medium-dependent interface crossover (auto-MDIX) feature is enabled by Note default. For configuration information for this feature, see the switch software configuration guide or the switch command reference on Cisco.com. Figure 2-6 Connecting to a 1000BASE-T SFP Module C a t a l y...
  • Page 32: Where To Go Next

    “Cable and Adapter Specifications” section on page B-4 cable-pinout descriptions. Where to Go Next To change the switch settings, you can use the switch default configuration or use any of the management options described in the “Management Options” section. Catalyst 2360 Switch Hardware Installation Guide 2-12 OL-22150-02...
  • Page 33: Installation Guidelines

    Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement 1029 Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 34: Tools That You Need

    The switch operates with either one or two active power supply modules. Two installed power supplies provide redundant power. Figure 3-1 shows the switch power supply. Figure 3-1 Power Supply for the Catalyst 2360 Switch 10 0- 24 0~ PW R OK 2- 1A , 50 -6 0H...
  • Page 35: Installing Or Replacing A Power Supply

    Install the new power supply into the slot, and gently push it in (Figure 3-3). When correctly inserted, Step 6 the power supply is flush with the switch rear panel. Move the release latch left to the locked position. Step 7 Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 36: Finding The Power Supply Serial Number

    LED and Table 1-5 describes the Power LED. Finding the Power Supply Serial Number If you contact Cisco Technical Assistance regarding a power supply module, you need to know the serial number. Figure 3-4 shows the serial number location.
  • Page 37: Fan Module Overview

    Chapter 3 Power Supply and Fan Module Installation Fan Module Overview Figure 3-4 Catalyst 2360 Switch Power Supply Serial Number SN: XXXNNNNXXXX Fan Module Overview The switch has one dual-direction fan module which comprises two fans (Figure 3-5). The orientation of the fan module sets the direction of the air flow through the switch—either air flow into the ports, or...
  • Page 38 1. Align this marker with one of the air flow direction markers on the switch chassis (Figures 3-7 through 3-10). Figure 3-6 Fan Module Rotation Figure 3-7 shows the fan orientation for airflow into the ports and shows the original switch chassis. Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 39 50 -6 0H 1 3 5 W 2- 1A , 50 -6 0H 1 3 5 W Figure 3-9 shows the fan orientation for airflow out of the ports and shows an original switch chassis. Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 40 An airflow direction label is on each side of the fan slot in the switch back panel. Align the fan-module airflow direction indicator (Figure 3-5) with one of the direction indicators on the back panel (Figures 3-7 through 3-10). Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 41: Replacing A Fan Module

    Finding the Fan Module Serial Number If you contact Cisco Technical Assistance regarding a fan module, you need to know the serial number. Figure 3-11 shows the serial number location.
  • Page 42 Chapter 3 Power Supply and Fan Module Installation Finding the Fan Module Serial Number Figure 3-11 Catalyst 2360 Switch Fan Module Serial Number SN: XXXNNNNXXXX Catalyst 2360 Switch Hardware Installation Guide 3-10 OL-22150-02...
  • Page 43: Chapter 4 Troubleshooting

    Switch POST Results See the “Verifying Switch Operation” section on page 2-4 for information on POST. POST failures are usually fatal. Contact your Cisco technical support representative if your switch does Note not pass POST. Switch LEDs If you have physical access to the switch, look at the port LEDs to troubleshoot the switch. See the “LEDs”...
  • Page 44: Switch Connections

    Verify that you are using the correct cable type. See Appendix B, “Connector and Cable • Specifications” for information. Look for loose connections. Sometimes a cable appears to be seated, but is not. Disconnect the cable • and then reconnect it. Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 45: 10/100/1000 Port Connections

    Re-enable the port if necessary. SFP and SFP+ Module Use only Cisco SFP or SFP+ modules in the switch. Each Cisco module has an internal serial EEPROM that is encoded with security information. This encoding provides a way for Cisco to identify and validate that the module meets the requirements for the switch.
  • Page 46: Switch Performance

    (Figure 1-1 on page 1-2). The switch LEDs blink after about 2 seconds. If the switch is not configured, the LEDs above the Mode button turn green. You can omit the next step. Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 47: Finding The Switch Serial Number

    Switch with the CLI-Based Setup Program” appendix. Finding the Switch Serial Number If you contact Cisco Technical Assistance, you need to know the switch serial number. Figure 4-1 shows the serial number location. You can also use the show version privileged EXEC command to see the switch serial number.
  • Page 48: Finding The Switch Serial Number

    Chapter 4 Troubleshooting Finding the Switch Serial Number Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 49: Appendix

    1. Power consumption values for the power consumed internally by the switch at 120 VAC 60 Hz. 2. Power rating values for the switch input power. 3. Switch chassis with no power supply, fan module, or SFP modules installed. Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 50: Power Supply Module Specifications

    Up to 10,000 ft (3049 m) Physical Specifications Dimensions (H x W x D) 1.64 x 1.81 x 7.89 in. (4.2 x 4.6 x 20 cm) Weight 0.54 lb. (0.25 kg) Operating Specification Airflow 60 cfm Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 51: Appendix

    Console Port, page B-4 • 10/100/1000 Ports All the 10/100/1000 ports use RJ-45 connectors and Ethernet pinouts. Figure B-1 10/100/1000 Port Pinouts Label 4 5 6 7 8 TP0+ TP0- TP1+ TP2+ TP2- TP1- TP3+ TP3- Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 52: Gigabit Ethernet Cx1 (Sfp+ Copper) Connectors

    When ordering or using CX1 cables, ensure that the version identifier is 2 or higher. The 10-Gigabit Ethernet optical modules use the connectors shown in Figure B-3 Figure B-4. Figure B-2 10-Gigabit Ethernet CX1 Copper Connector (example) SFP Module Connectors Figure B-3 Duplex LC Cable Connector Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 53: 10/100 Ethernet Management Port

    4 5 6 7 8 TP0+ TP0- TP1+ TP2+ TP2- TP1- TP3+ TP3- 10/100 Ethernet Management Port The 10/100 Ethernet management port uses RJ-45 connectors with Ethernet pinouts. Figure B-6 shows the pinouts. Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 54: Console Port

    B-8). The USB Type A-to-USB mini-Type B cable is not supplied. You can order an accessory kit (part number 800-33434) that has this cable. Figure B-8 USB Type A-to-USB 5-Pin Mini-Type B Cable Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 55: Cables And Adapters

    722 feet (220 m) 62.5/125 722 feet (220 m) (SFP-10G-LRM) 50/125 328 feet (100 m) 50/125 722 feet (220 m) 50/125 2000 722 feet (220 m) 10GBASE-LRM 1310 G.652 — 32,810 feet (10 km) (SFP-10G-LRM-SM) Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 56: Cable Pinouts

    Router or PC 1 TPO+ 1 TP1+ 2 TPO- 2 TP1- 3 TP1+ 3 TPO+ 6 TP1- 6 TPO- 4 TP2+ 4 TP3+ 5 TP2- 5 TP3- 7 TP3+ 7 TP2+ 8 TP3- 8 TP2- Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 57 1 RD+ 2 RD– 2 RD– Figure B-13 Identifying a Crossover Cable Pin 1 on one connector and pin 8 on the other connector should be the same color. Pin 1 Pin 8 Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 58: Console Port Adapter Pinouts

    RJ-45-to-DB-9 Console Port (DTE) Terminal Adapter Device Signal DB-9 Pin Signal Table B-3 Console Port Signaling with a DB-25 Adapter Switch Console RJ-45-to-DB-25 Console Port (DTE) Terminal Adapter Device Signal DB-25 Pin Signal Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 59: Appendix

    Setup Program You can use the command-line interface (CLI) setup procedure for a standalone switch. To use Express Setup, see the Cisco CGS 2360 Getting Started Guide. Before connecting the switch to a power source, review the safety warnings in Chapter 2, “Switch Installation,”...
  • Page 60 Connect the RJ-45-to-DB-9 adapter cable to the 9-pin serial port on the PC. Connect the other end to the Step 1 switch console port (Figure C-1). Figure C-1 Connecting the RJ-45 Console Cable to the Catalyst 2360 Switch C O N S O C O N S O CO NS OL MG MT BA SE T...
  • Page 61 • “Installing the Cisco Microsoft Windows 2000 USB Driver” section on page C-5 • “Installing the Cisco Microsoft Windows Vista and Windows 7 USB Driver” section on page C-5 • Figure C-2 Connecting the USB Console Cable to the Catalyst 2360 Switch...
  • Page 62: Installing The Cisco Microsoft Windows Usb Device Drivers

    Installing the Cisco Microsoft Windows XP USB Driver From Cisco.com, get the Cisco_usbconsole_driver. file and unzip it. Step 1 You can download the driver file from the Cisco.com software download site. Note For 32-bit Windows XP, double-click the setup.exe file in the Windows_32 folder. For 64-bit Windows Step 2 XP, double-click the setup(x64).exe file in the Windows_64 folder.
  • Page 63: Installing The Cisco Microsoft Windows 2000 Usb Driver

    Accessing the CLI Through the Console Port Installing the Cisco Microsoft Windows 2000 USB Driver From Cisco.com, get the Cisco_usbconsole_driver. file and unzip it. Step 1 You can download the driver file from the Cisco.com software download site. Note Double-click the file setup.exe. Step 2 The Cisco Virtual Com InstallShield Wizard begins.
  • Page 64: Uninstalling The Cisco Microsoft Windows Vista And Windows 7 Usb Driver

    You need to complete the setup program that runs after the switch powers on. You must assign an IP address and other configuration information necessary for the switch to communicate with the local routers and the Internet. This information is also needed to use the device manager or Cisco Network Assistant to configure and manage the switch.
  • Page 65: Completing The Setup Program

    Enter the interface name (physical interface or VLAN name) of the connection to the management Step 7 network, and press Return. For this release, always use vlan1 as that interface. Enter interface name used to connect to the Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 66 [1] Return back to the setup without saving this config. [2] Save this configuration to nvram and exit. Choose (2) to save the configuration to NVRAM to use it the next time the switch reboots. Enter your selection [2]:2 Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 67 Make your selection, and press Return. The switch now runs this default configuration. If you want to change this configuration or perform other management tasks, see the “Management Options” section on page 1-10. Catalyst 2360 Switch Hardware Installation Guide OL-22150-02...
  • Page 68 Appendix C Configuring the Switch with the CLI-Based Setup Program Entering the Initial Configuration Information Catalyst 2360 Switch Hardware Installation Guide C-10 OL-22150-02...
  • Page 69 USB console port default setting 2-11 code compliance warning troubleshooting command-line interface See CLI connecting to SFP and SFP+ modules 2-9 to 2-11 bodily injury protection warning connectors and cables B-1 to B-8 Catalyst 2360 Switch Hardware Installation Guide IN-1 OL-22150-02...
  • Page 70 2-8 to 2-9 described site requirements Express Setup starting the terminal emulation software C-2, C-4 accessing CLI by using See also procedures for initial switch configuration using to clear switch IP address Catalyst 2360 Switch Hardware Installation Guide IN-2 OL-22150-02...
  • Page 71: Ports B

    1-11 See also PoE noise, electrical POST LEDs 2-4, 4-1 results power outside connections warning connecting to overheating warning power connection warning power on power-on self test See POST power specifications Catalyst 2360 Switch Hardware Installation Guide IN-3 OL-22150-02...
  • Page 72: Console Port B

    Ethernet and fiber cables servicing equipment warning link status setup program ping end device POST serial number location spanning tree loops speed, duplex, and autonegotiation switch performance with LEDs Catalyst 2360 Switch Hardware Installation Guide IN-4 OL-22150-02...
  • Page 73: Uninstalling The Cisco Microsoft Windows Usb Driver C

    USB Type A interface warnings code compliance connecting outside of building connecting the power defined disposal of product Ethernet cables ground connection installation overheating preventing bodily injury restricted access area servicing equipment stacking equipment weight Catalyst 2360 Switch Hardware Installation Guide IN-5 OL-22150-02...
  • Page 74 Index Catalyst 2360 Switch Hardware Installation Guide IN-6 OL-22150-02...

Table of Contents