Notes
When you select an M/E reentry signal as material for
input to the color corrector, 1H delay occurs to the output
signal of M/E.
626

Settings Relating to Function Links (Link Menu)

Settings Relating to
Function Links (Link
Menu)
Carry out setup relating to links by displaying the Switcher
>Link menu.
To display the Link menu
In the Engineering Setup menu, select VF3 'Switcher' and
HF6 'Link.'
The status area shows the current link information.
The following functions are available here.
• Internal Bus Link: Make a setting of the bus link
function that links together two buses internal to the
switcher.
• GPI Link: Make settings for linking any cross-point
buttons or [CUT] and [AUTO TRANS] buttons in the
cross-point control block and GPI output ports.
• M/E Link: Make settings to link together two M/E
banks.
• Key Trans Link: Make settings to link key transitions.

Setting a Cross-Point Button Link

To link together two buses internal to the switcher, use the
following procedure.
1
In the Switcher >Link menu, press [Internal Bus Link].
The Internal Bus Link menu appears.
The status area shows the link source and link
destination buses, and link table information.
2
Using any of the following methods, select what
setting applies to.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Knob Parameter Adjustment
1
Link No
Link number
3
Press [Link Bus Select].
The Link Bus Select menu appears.
The status area lists the current setting status of the
selected link and the buses that can be selected.
4
In the <Bus Select> group, select [Master Bus] (link
source bus).
Setting values