Table of Contents

Advertisement

Quick Links

10K4 2.5kW
Amplifier
User Manual
Order code: AMP80

Advertisement

Table of Contents
loading

Summary of Contents for Zenith 10K4

  • Page 1 10K4 2.5kW Amplifier User Manual Order code: AMP80...
  • Page 2: Table Of Contents

    7.3 Signal flow and headroom ......................15 7.3.1 Signal flow block diagram ......................15 7.3.2 Headroom, sensitivity and VPL/Gain settings ................16 7.4 Audio input and output ........................17 7.4.1 Balanced input connections ......................17 7.4.2 Unbalanced input connections ....................17 Zenith 10K4 Amplifier Manual...
  • Page 3 7.6.4 Performance, warning and fault indicators ................. 24 7.7 2Ω load overheat protection ......................24 7.8 Amplifier hot swap modules ......................25 8 APPENDIX ..........................25 8.1 Maintenance ............................ 25 9 TECHNICAL SPECIFICATIONS ....................26 10 SAFETY ADVICE AND WARRANTY INFORMATION ............... 27 Zenith 10K4 Amplifier Manual...
  • Page 4: Approvals

    2 APPROVALS 3 WARNINGS 3.1 Explanation of graphical symbols 3.1.1 WARNING 3.1.2 CAUTION 3.2 Important safety instructions Zenith 10K4 Amplifier Manual...
  • Page 5: User Responsibility

    - Reorient the antenna. - Increase the separation between the equipment and receiver. Zenith 10K4 Amplifier Manual...
  • Page 6: Welcome

    Class D amplifier with the high sonic quality protection circuitry. To facilitate timely installation associated with Class B designs. Class TD also and use of this 10K4 product, we have included a incorporates the same basic concepts behind Class Quick Guide Overview (section 6). This brief...
  • Page 7: Amplifier Hot Swap Modules

    4.2.5 Amplifier hot swap modules The 10K4 amplifier is equipped with Hot Swap module technology. The output modules may be removed and replaced without the need to power down the amplifier. 4.2.6 2Ω load overheat protection In the situation the amplifier is used to power 2Ω...
  • Page 8: Installation

    5 INSTALLATION 5.1 Unpacking Carefully open the shipping carton and check for any noticeable damage. The 10K4 power amplifier is tested and inspected before leaving the factory and should arrive in perfect condition. If any damage is discovered, please notify the shipping company immediately.
  • Page 9: Cooling

    Front-to- rear airflow is preferred as cooler air is present at The 10K4 amplifier draws cool air in via the front the front in nearly all applications. (This allows panel and exhausts via the rear. Care should be...
  • Page 10: Operating Voltage

    LED will illuminate. connecting to an incorrect type of AC mains. Inrush power is controlled and limited during soft- 10K4 switch mode amplifiers use primary switching. start, enabling multiple amplifiers to be powered up Because the mains power is rectified directly before simultaneously.
  • Page 11: Quick Guide Overview

    VPL DIP-switch is set to maximum at the specified nominal load, the amplifier channel is able to deliver maximum rated output power. (PWR) Power on (Blue). - It's normal for the LED to illuminate "BLUE" during power on. Zenith 10K4 Amplifier Manual...
  • Page 12: Rear Panel Overview

    6.2 Rear panel overview Rear view of four-channel model fitted with SpeakON connectors Zenith 10K4 Amplifier Manual...
  • Page 13: Configuration Section

    6.2.3 Input and output connectors The amplifier of 10K4 is equipped with balanced XLR-F input connectors. SpeakON output connectors (SP). For specific configuration and wiring information, see section 7.4. - Audio inputs – four channel models Input connectors - SpeakON outputs –...
  • Page 14: Changing The Amplifier Hot Swap Modules

    When need to pull out the module, stirring the plug in/out bar to the handle (right side), the module will draw out from the position automatically, and then pull out the module easily and simple. - Change modules one at a time. Do not repeatedly insert/remove the modules. Zenith 10K4 Amplifier Manual...
  • Page 15: Operation And Performance

    Protection, Faults and Warnings section for further details. 7.3.1 Signal flow block diagram The input stage of 10K4 amplifiers has a high sensitivity to provide ample system headroom. This in effect means that the input stage is almost impossible to clip.
  • Page 16: Headroom, Sensitivity And Vpl/Gain Settings

    The chart to the follow of the drawing below show - When bridging two channels, you must add +6dB to input sensitivity for a 10K4 with a 8Ω load and 150V the input sensitivity to achieve maximum output peak (max.) and 38V peak (min.) respectively for the...
  • Page 17: Audio Input And Output

    A typical output source (e.g. a DSP crossover unit) can drive up to four amplifier channels before external line-drivers might be required to buffer the signal. SpeakON inputs – four channel models Zenith 10K4 Amplifier Manual...
  • Page 18 Channel A+B, provides outputs for both Channel A and Channel B. This output is useful when wiring the amplifier for bridged mono operation. See section 7.4.6. The left SpeakON connector provides an output for Channel B only. Connect the + and -loudspeaker cables as shown in the illustrations below. Zenith 10K4 Amplifier Manual...
  • Page 19: Output Bridge Mode

    The unique adjustable input gain feature of the 10K4 amp li fie r makes it easier to attain the - Use a high quality stranded loudspeaker cable, and optimum balance between headroom and signal-to- keep cable runs as short as possible.
  • Page 20: Output Voltage Peak Limiter (Vpl)

    Voltage Peak Limiter (VPL) is a unique feature in amplifier will not be damaged by forcing the 10K4 amplifiers. It is used to select the maximum amplifier to deliver current levels to the outputs that power available on each output channel. VPL levels exceed the physical limits of the transistors.
  • Page 21: Protection, Faults And Warnings

    7.5 Protection, faults and warnings 7.5.1 Introduction The 10K4 amplifier incorporates a sophisticated and comprehensive set of protection features. Faults and warnings are indicated on the front panel and reported. 7.5.2 Safe Operating Area Detector (SOAD) The Safe Operating Area Detector (SOAD) compares output voltage against output current to ensure that the output transistors are working inside their safe.
  • Page 22: High Impedance Warning (Open Load)

    This can result in tripping of fast- acting amplifier has gone into maximum current protection. mains breakers. Such is not the case with 10K4 This situation is caused by an excessive input signal amplifiers. The 10K4 amplifiers have very low inrush and is not due to a short circuit.
  • Page 23: Front Panel Monitoring And Adjustments

    The potentiometer's operational range is 0dB to minus infinity. Attenuation is logarithmic, with -10dB at the 12 o'clock position. 7.6.3 Mute indication Individual channel Mute is indicated by illumination of the red MUTE LED provided for each channel. Zenith 10K4 Amplifier Manual...
  • Page 24: Performance, Warning And Fault Indicators

    The amplifier requires servicing before placing back in operation. 7.7 2Ω load overheat protection In the situation the amplifier is used to power 2Ω loads, the internal monitoring system will reduce the output power automatically to prevent amplifier overheat. Zenith 10K4 Amplifier Manual...
  • Page 25: Amplifier Hot Swap Modules

    The module incorporates a lever system together with a card edge style connection system secured by an automatic spring locking mechanism. The 10K4 amplifier modules rely on all four modules being installed for cooling and air management to be effective. Do not operate the amplifier for extended periods without all four modules installed.
  • Page 26: Technical Specifications

    9 TECHNICAL SPECIFICATIONS Following are the 10K4 technical specifications. These figures are accurate at the time of printing but please note that all figures are subject to change without notice. For the most accurate and current information available, please visit www.prolight.co.uk...
  • Page 27: Safety Advice And Warranty Information

    HIGH VOLTAGE-RISK OUT OF DAMP/HUMID OF ELECTRIC SHOCK!! ENVIRONMENTS IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment. OPERATING DETERMINATIONS Zenith 10K4 Amplifier Manual...
  • Page 28 Zenith 10K4 Amplifier Manual...

This manual is also suitable for:

Amp80

Table of Contents