Grounding The Switch - Cisco IE 3000 Hardware Installation Manual

Table of Contents

Advertisement

Verifying Switch Operation
Obtain these necessary tools and equipment:

Grounding the Switch

To ground the switch to earth ground by using the ground screw, follow these steps. Make sure to follow
any grounding requirements at your site.
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
Warning
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection
authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024
This equipment is intended to be grounded to comply with emission and immunity requirements.
Warning
Ensure that the switch functional ground lug is connected to earth ground during normal use.
Statement 1064
Use at least a 4mm
Note
Step 1
Use a standard Phillips screwdriver or a ratcheting torque flathead screwdriver with a Phillips head to
remove the ground screw from the front panel of the switch. Store the ground screw for later use.
To make sure that the equipment is reliably connected to earth ground, follow the grounding procedure
Caution
instructions, and use a UL-listed ring terminal lug suitable for number 10-to-12 AWG wire, such as
Thomas & Bett part number 10RCR or equivalent.
Use a wire-stripping tool to strip the 10- gauge wire to 0.5 inch (12.7 mm) ± 0.02 inch (0.5 mm). See
Step 2
Figure
Cisco IE 3000 Switch Hardware Installation Guide
B-18
Ratcheting torque flathead screwdriver that exerts up to 15 inch-pounds (in-lb) of pressure
Ring terminal lug (such as Thomas & Bett part number 10RCR or equivalent)
Crimping tool (such as Thomas & Bett part number WT2000, ERG-2001, or equivalent)
10-gauge copper ground wire (such as Belden part number 9912 or equivalent)
For DC power connections, use UL- and CSA-rated, style 1007 or 1569 twisted-pair copper
appliance wiring material (AWM) wire (such as Belden part number 9318).
Wire-stripping tools for stripping 10- and 18-gauge wires
2
conductor to connect to the external grounding screw.
B-9.
Appendix B
Installation In a Hazardous Environment

Hide quick links: