Charge Current Compensation Settings (Read/Write Grouped Setting); Undercurrent (Read/Write Grouped Setting); Cold Load Pickup (Read/Write Setting) (2 Modules); Broken Rotor Bar Detection (Read Only Actual Values) - GE UR Series Manual

Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

MEMORY MAP
Products
Address Register name
"
9E8A

Charge Current Compensation Settings (Read/Write Grouped Setting)

L60
9EF0
"
9EF1
"
9EF3
2
"
9EF4

Undercurrent (Read/Write Grouped Setting)

M60
9F00
"
9F01
"
9F02
"
9F03
"
9F04
"
9F05
"
9F06
"
9F07
"
9F09
"
9F0A
"
9F0B
"
9F0C
"
9F0D
"
9F0E
"
9F0F
"
9F10
"
9F11
"
9F13

Cold Load Pickup (Read/Write Setting) (2 Modules)

F60
A000
"
A001
"
A003
"
A005
"
A006
"
A008
"
A009
"
A00A

Broken Rotor Bar Detection (Read Only Actual Values)

M60
A020
"
A021
"
A022
"
A023
"
A024
"
A026
"
A027
"
A028
2-128
...Repeated for Voltage Differential 3
Charging Current Compensation Factor
Charging Current Compensation Block
Charging Current Compensation Positive-
Sequence Xc
Charging Current Compensation Zero-
Sequence Xc
Undercurrent Function
Undercurrent Speed 1 Start Block Delay
Undercurrent Speed 1 Alarm Pickup
Undercurrent Speed 1 Alarm Pickup Delay
Undercurrent Speed 1 Trip Pickup
Undercurrent Speed 1 Trip Pickup Delay
Undercurrent Speed 1 Trip Reset Delay
Undercurrent Speed 1 Block
Undercurrent Target
Undercurrent Events
Undercurrent Speed 2 Start Block Delay
Undercurrent Speed 2 Alarm Pickup
Undercurrent Speed 2 Alarm Pickup Delay
Undercurrent Speed 2 Trip Pickup
Undercurrent Speed 2 Trip Pickup Delay
Undercurrent Speed 2 Trip Reset Delay
Undercurrent Speed 2 Block
Reserved (2 items)
Cold Load Pickup 1 Function
Cold Load Pickup 1 Initiate
Cold Load Pickup 1 Block
Outage Time Before Cold Load Pickup 1
On Load Time Before Reset 1
Cold Load Pickup 1 Source
Cold Load Pickup 1 Reserved
...Repeated for Cold Load Pickup 2
Broken Rotor Bar Component Level
Broken Rotor Bar Component Frequency
Motor Load at Broken Rotor Bar Calculation 0 to 1.5
Motor Load Deviation at Broken Rotor Bar
Calculation
Time Stamp at Broken Rotor Bar
Calculation
Maximum Broken Rotor Bar Component
Level
Maximum Broken Rotor Bar Component
Frequency
Motor Load at Broken Rotor Bar Maximum 0 to 1.5
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0 to 1
---
1
0 to 4294967295
---
1
0.100 to 65.535
kOhm
0.001 F001
0.100 to 65.535
kOhm
0.001 F001
0 to 1
---
1
0.00 to 600.00
s
0.01
0.10 to 0.95
× FLA
0.01
0.00 to 600.00
s
0.01
0.10 to 0.95
× FLA
0.01
0.00 to 600.00
s
0.01
0.00 to 600.00
s
0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0.00 to 600.00
s
0.01
0.10 to 0.95
× FLA
0.01
0.00 to 600.00
s
0.01
0.10 to 0.95
× FLA
0.01
0.00 to 600.00
s
0.01
0.00 to 600.00
s
0.01
0 to 4294967295
---
1
0 to 1
---
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 1000
s
1
0 to 1000000
s
0.001 F003
0 to 5
---
1
0 to 65535
---
1
–100 to 0
dB
0.1
0 to 76
Hz
0.01
× FLA
0.01
0 to 1.5
× FLA
0.01
0 to 4294967295
---
1
–100 to 0
dB
0.1
0 to 76
Hz
0.01
× FLA
0.01
UR SERIES – COMMUNICATIONS GUIDE
Format
Default
F102
0 (Disabled)
F300
0
100
100
F102
0 (Disabled)
F001
50
F001
70
F001
200
F001
70
F001
100
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
50
F001
70
F001
200
F001
70
F001
100
F001
100
F300
0
F001
0
F102
0 (Disabled)
F300
0
F300
0
F001
1000
100000
F167
0 (SRC 1)
F001
0
F002
–1000
F001
0
F001
0
F001
0
F050
0
F002
–1000
F001
0
F001
0