Philips ADIM ADM0101 Installation Instructions Manual

Philips ADIM ADM0101 Installation Instructions Manual

Philips integration solution installation instructions

Advertisement

Quick Links

Eng
Philips
Communication,
Security & Imaging

Advertisement

Table of Contents
loading

Summary of Contents for Philips ADIM ADM0101

  • Page 1 Philips Communication, Security & Imaging...
  • Page 2: Important Safeguards

    IMPORTANT SAFEGUARDS 1. Read Instructions - All safety and operating instructions should be read before the unit is operated. 2. Retain Instructions - The safety and operating instructions should be retained for future reference. 3. Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to.
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT OPEN COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flash with an arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage”...
  • Page 4 SICHERHEITSHINWEISE VORSICHT ELEKTRISCHE SPANNUNG. NICHT ÖFFNEN! VORSICHT: DAS GEHÄUSE ZUR VERMEIDUNG VON ELEKTRISCHEN SCHLÄGEN NICHT ÖFFNEN. DAS GERÄT ENTHÄLT KEINE VOM BENUTZER ZU WARTENDEN TEILE. REPARATUREN NUR VON FACHPERSONAL AUSFÜHREN LASSEN. Das Blitzsymbol im gleichseitigen Dreieck soll den Benutzer auf nicht isolierte “gefährliche Spannung” im Produkt hinweisen, die ausreichend stark sein kann, um die Gefahr von elektrischen Schlägen für Menschen darzustellen.
  • Page 5 VEILIGHEIDSMAATREGELEN VOORZICHTIG GEVAAR VOOR ELEKTRISCHE SCHOK. NIET OPENEN! VOORZICHTIG: MAAK HET APPARAAT NIET OPEN OM DE KANS OP ELEKTRISCHE SCHOKKEN TE VERMIJDEN. BEVAT GEEN ONDERDELEN DIE DOOR DE GEBRUIKER MOETEN WORDEN ONDERHOUDEN. LAAT ONDERHOUD EN REPARATIES UITVOEREN DOOR BEVOEGDE TECHNICI. Het symbool ‘Bliksemflits met pijlkop’...
  • Page 6 MEDIDAS DE SEGURANÇA CUIDADO RISCO DE CHOQUE ELÉCTRICO. NÃO ABRIR! CUIDADO: PARA REDUZIR O RISCO DE CHOQUE ELÉCTRICO, NÃO ABRA AS TAM- PAS. O INTERIOR NÃO CONTÉM PEÇAS QUE NECESSITEM DE MANUTENÇÃO. A MANUTENÇÃO DEVE SER EFECTUADA POR PESSOAL DE ASSISTÊNCIA TÉCNICA QUALI- FICADO.
  • Page 7: Table Of Contents

    TABLE OF CONTENTS 1 PRODUCT DESCRIPTION ...8 1.1 Models ...8 1.2 Features...8 2 UNPACKING...8 2.1 Package Contents ...8 3 SYSTEM OVERVIEW ...8 4 ADIM CONNECTIONS AND CONFIGURATION...10 4.1 DVR Configuration (See DVR manual) ...10 4.2 IntuiKey Keyboard and Serial Hub Connections ...10 4.3 ADIM PC is pre-configured as follows ...10 4.4 Primary DVR Connections...10 4.5 Backup DVR and Review Monitor Connections (Optional) ...10...
  • Page 8: Product Description

    ADIM is a powerful security and surveillance solution that ™ combines the power and features of the Philips Allegiant matrix switcher with the speed and quality of digital video recording. This tightly integrated solution uses the IntuiKey keyboard to control all cameras, monitors and digital video recorders. With the push of a button, the DVR will playback video from the current camera and display it on the specified CCTV monitor.
  • Page 9 Keyboards may be connected to the Allegiant for live monitoring and camera control. • ADIM can only be used with compatible Philips DVRs. (See Appendix D.) • Only one user at a time can access a particular DVR. To...
  • Page 10: Adim Connections And Configuration

    • Connect the Allegiant Monitor Outputs to the Backup or Review DVR video inputs. • Connect the MON A output of the DVRs to an Allegiant input. Inputs PHILIPS ALLEGIANT Video Matrix 101 102 234 536 Loop Out Video Mon A...
  • Page 11: Network Connections

    Subnet mask: 255.255.255.0 • Default Gateway: 10.10.0.1 Philips recommends that your IT department perform all network and set up configuration. NOTE: The PC is pre-configured to communicate with the Serial Hub that is shipped with ADIM. If a different Serial Hub is used with the system, the PC must be reconfigured.
  • Page 12: Adim Configuration

    ADIM CONFIGURATION The ADIM software is pre-loaded. No software installation is required. Open the ADIM Application by double clicking the ADIM icon on your desktop. Logging ON and User Levels • Log in with a user name and password. • If configuring the system, logon as a user with Installer or Administrator privileges.
  • Page 13: Operation

    4. If it is a new document, or if the Allegiant system is not on- line, select <Allegiant> <<Display Allegiant Document>>: Allegiant Document: 5. Using the instructions in the Master Control Software For Windows, configure the communication parameters <<Transfer>> <<<Communication Setup>>>: Set the communication parameters for the Allegiant and press Go Online.
  • Page 14: Other Configuration

    Items from DVR Configuration page ITEM Explained Identifies 1 to 800 Hi-Qs Hi-Q Number (Not changeable) IP address Hi-Q IP address Determines how the Hi-Q is Primary, Monitor configured into the system Review or Backup (Primary, Backup, Review) Enabled Status Used to bring a Hi-Q online Allegiant Input Must be a valid logical camera...
  • Page 15: Status And Monitoring Page

    Status and Monitoring Page Table Element Hi-Q number Hi-Q Type Hi-Q Status Hi-Q Input Number Allegiant Logical Camera Number Camera Status BUTTON: Switch video from selected Primary Hi-Q to a Backup Hi-Q BUTTON: Set Selected Backup Hi-Q to “Available” BUTTON: Silence Beep BUTTON: Add Manual Event Message ADIM Messages BUTTON: Open Log File...
  • Page 16: Allegiant Camera Title Transfer Dialog

    NOTES: • New Log files are created daily upon the occurrence of the first event after 12:00am. Otherwise, new entries are appended to the existing log file upon starting the application. • Log files are easily manipulated into MS Excel or MS Access files for reporting.
  • Page 17: Adim Keyboard Operation

    • Returns the Live camera view (direct from the Allegiant) to the present monitor. NOTE: Details regarding the functions of the other buttons may be found in the IntuiKey Keyboard and Philips DVR Instruction Manuals. Keyboard Error Handling If the IntuiKey keyboard fails to communicate with the system, an error message, ADIM Communication Error (along with an audible beep) displays on the keyboard.
  • Page 18: Troubleshooting

    TROUBLESHOOTING Problem Keyboards are not communicating with the ADIM Software Pressing ADIM Controls on the IntuiKey results in the Allegiant monitor displaying the output of the Hi-Q’s MON A in Live mode instead of Playback mode. (No error messages are displayed on the Allegiant monitor.) Keyboards display ADIM Off-line Error Message 100...
  • Page 19: Appendix A - Event Logs

    APPENDIX A – EVENT LOGS Monitor Likely Source Event Message of Error Info Primary or Review DVR Error! ADIM Software Hi-Q Failure Primary or Review Hi-Q Disk Array DVR Error! Failure Backup Hi-Q BU DVR Error ADIM Software Failure Backup Hi-Q Disk BU DVR Error Array Failure Hi-Q Disabled...
  • Page 20 APPENDIX A – EVENT LOGS (…continued) Monitor Likely Source Event Message of Error Info Allegiant On-Line ADIM Software Allegiant Off-Line ADIM Software Hi-Q Low Power DVR Voltage Supply Voltage Camera Dark Dark Alarm CamXXXX Camera Failure Fail CamXXXX (Video Loss Alarm) Manual Alarm Auxiliary Alarm Keyboard...
  • Page 21 APPENDIX A – EVENT LOGS (…continued) Monitor Likely Source Event Message of Error Info Recording Status Change 2 Recording Status Change 3 Recording Status Change 4 Recording Status Change 5 Hi-Q Timeout ADIM Software Hi-Q Delayed-OK ADIM Software Disk Array Disk Array! ADIM Software Not Found...
  • Page 22: Appendix B - Technical Specs

    APPENDIX B – TECHNICAL SPECS ADIM Components (included): Industrial PC: Rack-mount industrial-grade Pentium 120 MB RAM (minimum), 8 GB hard drive (minimum), CD-ROM drive, floppy drive, keyboard, mouse, 10/100BaseT- compatible (RJ-45), keyboard/mouse rack-mount shelf, and Windows NT ® 120/220 VAC, 50/60 Hz. Monitor: 14-inch SVGA (including rack-mount hardware) 120/220, VAC, 50/60 Hz...
  • Page 23: Appendix C - Recommended Network Switches

    1. Select the Monitor you wish to review 2. Select camera number that corresponds to the Hi-Q’s MON A output that is connected to the Allegiant Input. (In Figure below this would be camera number 29) ALLEGIANT Video Matrix Monitor Outputs PHILIPS 10 11 12 13...
  • Page 24 © 2002 by Philips Communication, Security & Imaging, Inc. All Rights Reserved. Philips Updated September 25, 2002. Data subject to change without notice. Refer to www.philipscsi.com for latest information. ® is a registered trademark of Philips Electronics N. A. Corp.

Table of Contents