Dell S5000 Configuration Manual

Dell S5000 Configuration Manual

Data center switch
Hide thumbs Also See for S5000:

Advertisement

Dell Networking S5000
Switch Configuration Guide for EqualLogic SANs
Dell Storage Engineering
April 2014
SISfeedback@Dell.com

Advertisement

Table of Contents
loading

Summary of Contents for Dell S5000

  • Page 1 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs Dell Storage Engineering April 2014 SISfeedback@Dell.com...
  • Page 2: Revisions

    April 2014 Minor update © 2014 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without the express written permission of Dell Inc. is strictly forbidden. For more information, contact Dell. Dell, the Dell logo, and the Dell badge, and EqualLogic are trademarks of Dell Inc.
  • Page 3: Table Of Contents

    Configure DCB policies ............................... 12 Apply policies to switch ports ............................. 12 Save configuration ................................ 12 Configure additional switches ............................ 12 Reverting from DCB to non-DCB configuration (Optional) .................... 13 Disable DCB ................................... 13 SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
  • Page 4 Configure UPM ports as Ethernet Pass-through (Optional) .................... 15 View the current configuration ..........................15 Configure port group 0 as Ethernet Pass-through ....................15 To revert Ethernet Pass-through to FC ports ......................16 Additional resources ..................................17 SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
  • Page 5: Introduction

    Introduction This document shows how to configure Dell™ Networking S5000 switches for use with EqualLogic™ PS Series storage using Dell best practices. The recommended configuration uses only Ethernet modules and uses link aggregation groups (LAGs) for inter-switch connections. Optional steps are provided in Section 3 to enable Data Center Bridging (DCB).
  • Page 6: Cabling Diagram

    Cabling diagram The cabling diagram shown below represents the Dell recommend method for deploying your servers and EqualLogic arrays. Figure 1 Cabling diagram SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
  • Page 7: Dell Recommended Switch Configuration

    Dell recommended switch configuration These steps outline how to configure two S5000 switches with a Link Aggregation Group (LAG) interconnect. The switches are interconnected using two 40 GbE Quad Small Form-factor Pluggable (QSFP) uplink ports, and the LAG is configured for Dynamic Link Aggregation Control Protocol (LACP).
  • Page 8: Configure Out Of Band (Oob) Management Port

    Option 1: You can enable ports individually by entering the port number FTOS(conf)#interface tengigabitethernet 0/0 FTOS(conf-if-te-0/0)#switchport FTOS(conf-if-te-0/0)#no shutdown FTOS(conf-if-te-0/0)#exit Option 2: You can enable multiple ports at once using the “range” parameter SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
  • Page 9: Enable Jumbo Frames

    FTOS(conf-if-po-1)#no shutdown FTOS(conf-if-po-1)#exit 2.12 Configure QSFP ports for LAG This step assigns the 40Gb QSFP ports to the Port Channel. FTOS(conf)#interface range fortyGigE 0/48 , fortyGigE 0/52 FTOS(conf-if-range-fo-0/48,fo-0/52)#mtu 12000 FTOS(conf-if-range-fo-0/48,fo-0/52)#no shutdown SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
  • Page 10: Save Configuration

    FTOS(conf-if-range-fo-0/48,fo-0/52)#port-channel-protocol lacp FTOS(conf-if-range-fo-0/48,fo-0/52-lacp)#port-channel 1 mode active FTOS(conf-if-range-fo-0/48,fo-0/52-lacp)#exit FTOS(conf-if-range-fo-0/48,fo-0/52)#exit FTOS(conf)#exit 2.13 Save configuration FTOS#copy running-config startup-config 2.14 Configure additional switch Repeat the commands from Section 2 to configure the second switch. SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
  • Page 11: Configure Data Center Bridging (Dcb) (Optional)

    Configure Data Center Bridging (DCB) (Optional) DCB is enabled by default. This section shows the steps required to configure DCB. Note: You must complete the Dell recommended switch configuration steps in Sections 2.1 to 2.14before configuring the switch for DCB mode.
  • Page 12: Configure Dcb Policies

    FTOS(conf)#interface range fortyGigE 0/48 - 60 FTOS(conf-if-range-fo-0/48-60)#dcb-map profile-name FTOS(conf-if-range-fo-0/48-60)#exit FTOS(conf)#exit Save configuration FTOS#copy running-config startup-config Configure additional switches Repeat the commands from Section 3 to configure DCB on additional switches. SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
  • Page 13: Reverting From Dcb To Non-Dcb Configuration (Optional)

    VLAN ID (typically 0 or 1) or a specific VLAN can be configured (for example, VLAN 100). If a non-default VLAN is configured, then any ports connected to the arrays must be configured as “untagged”. SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
  • Page 14: Save Configuration

    Use the steps below to configure the default VLAN on the switch. FTOS#configure FTOS(conf)#no interface vlan vlan-id FTOS(conf)#exit Save configuration FTOS#copy running-config startup-config Configure additional switch Repeat the commands in Section 4 to disable DCB on any additional switches. SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
  • Page 15: Configure Upm Ports As Ethernet Pass-Through (Optional)

    Changing port mode on slot 0 port-group 0 will make interface configs of 0 and 1 obsolete after a save and reload. [confirm yes/no]:yes Please save and reload for the changes to take effect. Note: Save and reload is required. SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
  • Page 16: To Revert Ethernet Pass-Through To Fc Ports

    Changing port mode on slot 0 port-group 0 will make interface configs of 0 and 1 obsolete after a save and reload. [confirm yes/no]:yes Please save and reload for the changes to take effect. Note: Save and reload is required. SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
  • Page 17: Additional Resources

    DellTechCenter.com is an IT Community where you can connect with Dell Customers and Dell employees for the purpose of sharing knowledge, best practices, and information about Dell products and your installations. Referenced or recommended Dell publications: ...