Configure DCB policies ............................... 12 Apply policies to switch ports ............................. 12 Save configuration ................................ 12 Configure additional switches ............................ 12 Reverting from DCB to non-DCB configuration (Optional) .................... 13 Disable DCB ................................... 13 SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
Page 4
Configure UPM ports as Ethernet Pass-through (Optional) .................... 15 View the current configuration ..........................15 Configure port group 0 as Ethernet Pass-through ....................15 To revert Ethernet Pass-through to FC ports ......................16 Additional resources ..................................17 SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
Introduction This document shows how to configure Dell™ Networking S5000 switches for use with EqualLogic™ PS Series storage using Dell best practices. The recommended configuration uses only Ethernet modules and uses link aggregation groups (LAGs) for inter-switch connections. Optional steps are provided in Section 3 to enable Data Center Bridging (DCB).
Dell recommended switch configuration These steps outline how to configure two S5000 switches with a Link Aggregation Group (LAG) interconnect. The switches are interconnected using two 40 GbE Quad Small Form-factor Pluggable (QSFP) uplink ports, and the LAG is configured for Dynamic Link Aggregation Control Protocol (LACP).
Option 1: You can enable ports individually by entering the port number FTOS(conf)#interface tengigabitethernet 0/0 FTOS(conf-if-te-0/0)#switchport FTOS(conf-if-te-0/0)#no shutdown FTOS(conf-if-te-0/0)#exit Option 2: You can enable multiple ports at once using the “range” parameter SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
FTOS(conf-if-po-1)#no shutdown FTOS(conf-if-po-1)#exit 2.12 Configure QSFP ports for LAG This step assigns the 40Gb QSFP ports to the Port Channel. FTOS(conf)#interface range fortyGigE 0/48 , fortyGigE 0/52 FTOS(conf-if-range-fo-0/48,fo-0/52)#mtu 12000 FTOS(conf-if-range-fo-0/48,fo-0/52)#no shutdown SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
FTOS(conf-if-range-fo-0/48,fo-0/52)#port-channel-protocol lacp FTOS(conf-if-range-fo-0/48,fo-0/52-lacp)#port-channel 1 mode active FTOS(conf-if-range-fo-0/48,fo-0/52-lacp)#exit FTOS(conf-if-range-fo-0/48,fo-0/52)#exit FTOS(conf)#exit 2.13 Save configuration FTOS#copy running-config startup-config 2.14 Configure additional switch Repeat the commands from Section 2 to configure the second switch. SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
Configure Data Center Bridging (DCB) (Optional) DCB is enabled by default. This section shows the steps required to configure DCB. Note: You must complete the Dell recommended switch configuration steps in Sections 2.1 to 2.14before configuring the switch for DCB mode.
VLAN ID (typically 0 or 1) or a specific VLAN can be configured (for example, VLAN 100). If a non-default VLAN is configured, then any ports connected to the arrays must be configured as “untagged”. SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
Use the steps below to configure the default VLAN on the switch. FTOS#configure FTOS(conf)#no interface vlan vlan-id FTOS(conf)#exit Save configuration FTOS#copy running-config startup-config Configure additional switch Repeat the commands in Section 4 to disable DCB on any additional switches. SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
Changing port mode on slot 0 port-group 0 will make interface configs of 0 and 1 obsolete after a save and reload. [confirm yes/no]:yes Please save and reload for the changes to take effect. Note: Save and reload is required. SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...
Changing port mode on slot 0 port-group 0 will make interface configs of 0 and 1 obsolete after a save and reload. [confirm yes/no]:yes Please save and reload for the changes to take effect. Note: Save and reload is required. SCG1007 Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs...