NEC UNIVERGE SV8300 Command Manual page 584

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
EA
Y
No.
MEANING
2
Fault information
and external alarm
(Display only)
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
1ST DATA
DATA
MEANING
040
Traffic of IP network exceeded
limit bandwidth
041
Traffic of IP network exceeded
warning bandwidth
042
Communication error occur-
rence between Main Unit and
Remote Unit
043
SIP trunk failure
048
CPU Program Upgrade
04A
Long call duration information
100
Power failure
102
DTI line failure
104
SV8300 Blade down
106
SV8300 Blade reset with
CME03
107
Lack of option value
108
Lack of Highway Channel
Fault Kind: Restoration
031
ISDN D-channel link connec-
tion returned to normal condi-
tion
032
CCIS link connection returned
to normal condition
035
Number of lockout stations re
stored to less than predeter-
mined number
036
DLC blade returned to normal
condition
2ND DATA
DATA
0
External Alarm Kind
0: Fault Memory
3
store/No output of
External Alarm
1: Fault Memory
store/External
Alarm is MN
NOTE 4
alarm
2: Fault Memory
store/External
Alarm is MJ alarm
3: No Fault Memory
store/No External
NOTE 5
Alarm output
NOTE 6
3-535
: Default
RELATED
COMMAND
MEANING
CM08>450
CM42>01
Continued on next page
NWA-033623-001 Rev.3.0
NOVEMBER/12/2008
CMEA