5-2.

Numerical Command

This command is used to specify numerical parameters. It is used also to return a numerical data such as
time data and CTL from this device. There are 3 formats available (byte-parameter input, multi-byte
parameter input, multi-type parameter input) as shown below.
Byte-parameter input
This is used to specify a 1-byte numerical parameter. NAK will be returned if a non-numerical command is
entered.
FWD SHUTTLE and REV SHUTTLE commands belong to this type.
Ex) Double speed playback
Speed data
Command
B5H
36H
Host
0AH
This device
"ACK"
Multi-byte parameter input
This is used to specify a multi-byte numerical parameter. Such a numerical parameter is composed of a
plurality of bytes including a sign code, and is always ended by ENTER (40H).
Each command has a fixed maximum number of bytes, and when this value is exceeded, the numerical part
that comes behind is valid. However, the sign command is given a special treatment.
CTL PRESET and SEARCH commands belong to this type.
Ex) An example of setting the preset value of CTL to "0:12:34:12"
Command
D8H
9AH
Host
This device
0AH
"ACK"
"2"
32H
33H
Host
This device
0AH
"ACK"
"2"
"ENTER"
32H
40H
Host
0AH
This device
"ACK"
14
0AH
"ACK"
"0"
"1"
30H
31H
0AH
0AH
"ACK"
"ACK"
"3"
"4"
"1"
34H
31H
0AH
0AH
"ACK"
"ACK"
0AH
"ACK"
0AH
"ACK"
0AH
"ACK"
HVO-500MD/550MD

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hvo-550md

Table of Contents