Message Lists

Warning messages
Symptom
High temp.! Light off in 1
min.
Frequency is out of
range!
Projector temperature is
high. Cooling Setting
should be "High" if
projector is being used at
high altitude.
Power Saving Mode is
set. Projector will
automatically enter
Standby Mode in 1
minute.
Caution messages
Symptom
x
Not applicable!
46
Message Lists
Cause and Remedy
Turn off the power.
Check to ensure that nothing is blocking the ventilation
holes.
Frequency is out of range. Input a signal that is within the
acceptable frequency range of the unit.
Check to ensure that nothing is blocking the ventilation
holes.
When using the unit at high altitude, set "Cooling Setting"
to "High."
Note
When temperature inside the unit remains high, "Cooling
Setting" is switched to "High" after 1 minute, then the fan
speed increases.
"Power Saving" is set to "Standby."
Note
If no signal is input, the power turns off after 1 minute, and
the projector goes into standby mode.
Cause and Remedy
No signal is input in the selected input. Check connections.
Press the appropriate button.
The operation to be activated by the button is currently
prohibited.
Page