Panasonic WJ-RT208 Operating Instructions Manual page 37

Digital disk recorder
Hide thumbs Also See for WJ-RT208:
Table of Contents

Advertisement

TERMINAL REC
Terminal Input
1
Alarm Output
0
Alarm Time
030
Rec. Interval
060
PTZ Preset
000
Rec. Channel
1
Rec. Quality
Normal
Period1
00: 00
Period2
00: 00
All
Terminal input connector: 1 - 8
Default: 1
Alarm output connector: 0 - 3
Default: 0 (0 indicates that there is no alarm signal
output.)
Alarm time: 000 - 999
Default: 030
Rec. Interval: 030 - 999
Default: 060
Camera preset position: 000 - 256
Default: 000
Recording channel: 0 - 8
Default: 1
Picture quality: "SP Fine/Fine/Good/Normal/Extended"
Default: "Normal"
Frame rate: "Full, 1/2F, 1/4F, 1/8F, 1/16F"
Default: "Full"
Stream type: "CBR/VBR"
Default: "CBR" (If screen changes seem extreme,
the setting made at "VBR" is preferable.)
Period: "Period1/Period2"
Default: 00: 00 - 24:00
When "On" is selected for "Period1" and/or "Period2",
alarm detection will be validated in the set period.
Notes:
1. When setting is completed, set "Period1" and/or
"Period2" at "On".
2. For [All] operation and functions, refer to the timer
recording explanation.
(4) When setting is completed, move the cursor to [OK]
and press the [SET] button.
Note: When trying to stop the recording by changing
the settings in the process of the terminal recording,
recording will not stop immediately. The terminal
recording will not stop unless time set for "Rec.
Interval" has been passed. To stop the terminal
recording, stop recording manually after changing
the settings for the terminal recording.
Sec
Sec
Full
CBR
24: 00
Off
24: 00
On
OK
Cancel
Video motion detector recording (VMD REC)
(1) Press the [MENU] button. "WJ-RT208 SETUP MENU"
appears. Move the cursor to "REC&EVENT SETUP" and
press the [SET] button. (Refer to steps (1) and (2) in
3.1.3.)
REC & EVENT
TIMER REC
TERMINAL REC
VMD REC
RECORD LENGTH
AUDIO SELECT
(2) Move the cursor to "VMD REC" and press the [SET] but-
ton.
VMD REC
Channel No.
1
Sensitivity
10
Area Setup
Set
Alarm Output
0
Rec. Interval
060
PTZ Preset
000
Rec. Quality
Normal
Period1
00: 00
Period2
00: 00
All
Camera ID: 1-8
Default: 1
Sensitivity: 01 - 99 (01 corresponds to the maximum
sensitivity.)
Default: 10
Area setup: 140 grid areas can be established inde-
pendently.
Default: All areas are not selected.
Alarm output connector: 0-3
Default: 0 (0 indicates that there is no alarm signal
output.)
Alarm time: 000-999
Default: 030
Rec. Interval: 030-999
Default: 060
Camera preset position: 000-256
Default: 000
Picture quality: "SP Fine/Fine/Good/Normal/Extended"
Default: "Normal"
030
Sec
Sec
Full
CBR
24: 00
Off
24: 00
Off
OK
Cancel