General; Long Term Storage; Other Storage Tips - Honeywell 0061520 Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

Maintenance

3.7 GENERAL

The generator should be started at least once every thirty days and
be allowed to run at least 30 minutes. If this cannot be done and
the unit must be stored for more than 30 days, use the following
information as a guide to prepare it for storage.
NEVER store engine with fuel in tank indoors
or in enclosed, poorly ventilated areas where
fumes may reach an open flame, spark or pilot
light as on a furnace, water heater, clothes
dryer or other gas appliance.
Allow unit to cool entirely before storage.


3.8 LONG TERM STORAGE

It is important to prevent gum deposits from forming in essential
fuel system parts such as the carburetor, fuel hose or tank during
storage. Also, experience indicates that alcohol-blended fuels
(called gasohol, ethanol or methanol) can attract moisture, which
leads to separation and formation of acids during storage. Acidic
gas can damage the fuel system of an engine while in storage.
To avoid engine problems, the fuel system should be emptied
before storage of 30 days or longer, as follows:
• A quality fuel stabilizer should be added to the existing fuel per
the manufacturers specifications.

 Drain fuel into approved container outdoors,
away from open flame. Be sure engine is cool.
Do not smoke.
• Start and run the engine for 10 - 15 minutes, after that time and
while the unit is running, turn the fuel shut-off valve OFF and run
until the engine stops from lack of fuel.
• Allow the engine to cool, then remove all gasoline from the fuel
tank. Use a commercially available, non-conductive vacuum
siphon. Drain oil from crankcase. Refill the crankcase with
recommended grade oil.
• Remove spark plug and spray with a quality fogging agent, or
pour about 1/2 ounce (15 ml) of engine oil into the cylinder.
Cover spark plug hole with rag. Pull the recoil starter a couple
times to lubricate the piston rings and cylinder bore. A fogging
agent can also be used in the place of oil.
16
Avoid spray from spark plug hole when

cranking engine.
• Install and tighten spark plug. Do not connect spark plug wire.
• Clean the generator's outer surfaces. Check that cooling air
slots and openings on generator are open and unobstructed.
• Store the unit in a clean, dry place.

3.9 OTHER STORAGE TIPS

• Do not store gasoline from one season to another.
• Replace the gasoline can if it starts to rust. Rust and/or dirt in
the gasoline will cause problems with the carburetor and fuel
system.
• If possible, store the unit indoors and cover it to give protection
from dust and dirt. BE SURE TO EMPTY THE FUEL TANK.
• If it is not practical to empty the fuel tank and the unit is to
be stored for some time, use a commercially available fuel
stabilizer added to the gasoline to increase the life of the
gasoline. Start and run the engine for 10 - 15 minutes, after that
time and while the unit is running, turn the fuel shut-off valve
OFF and run until the engine stops from lack of fuel.
• Cover the unit with a suitable protective cover that does not
retain moisture.
NEVER cover the generator while engine and

exhaust areas are warm.

Advertisement

Table of Contents