Motorola MSC8101 ADS User Manual page 81

Motorola msc8101 ads motorola metrowerks user's manual
Table of Contents

Advertisement

TABLE B1-2. P1 - System Expansion - Interconnect Signals
Pin No.
Signal Name
C11
IRQ6b
C12
IRQ7b
C13
GND
C14
EXPD0
C15
EXPD1
C16
EXPD2
C17
EXPD3
C18
EXPD4
C19
EXPD5
C20
EXPD6
C21
EXPD7
C22
EXPD8
C23
EXPD9
C24
EXPD10
C25
EXPD11
C26
EXPD12
C27
EXPD13
C28
EXPD14
C29
EXPD15
C30
IRQ4b
C31
IRQ5b
B-80
Freescale Semiconductor, Inc.
Attribute
I,P.U.
Interrupt Request 6 . Connected to MSC8101's DP6//IRQ6b/
DACK3 signal. Pulled up on the ADS with a 10 KΩ resistor. This
line is shared with the ATM UNI's interrupt line and therefore,
when driven by an external tool, MUST be driven with an Open
Drain gate. Failure to do so may result in permanent damage
to the MSC8101 or to ADS logic.
I.P.U.
Interrupt Request 7 . Connected to MSC8101's DP7/IRQ7b/
DACK4 signal. Pulled up on the ADS with a 10 KΩ resistor. This
line is shared with the Fast Ethernet transceiver's interrupt line
and therefore, when driven by an external tool, MUST be driven
with an Open Drain gate. Failure to do so might result in
permanent damage to the MSC8101 and / or to ADS logic.
P
Digital Ground. Connected to main GND plane of the ADS.
I/O, T.S.
Expansion Data (0
PPC bus D(0:15) lines, controlled by on-board logic. These lines
will be driven only if BTOLCS1b or BTOLCS2b are asserted.
Otherwise they are tristated.
The direction of these lines is determined by buffered BCTL0, in
function of R~/W.
I.P.U.
Interrupt Request 4. Connected to MSC8101's DP4/IRQ4b/
DREQ3 signal. Pulled up on the ADS with a 10 KΩ resistor. This
line is shared with the Fast Ethernet transceiver's interrupt line
and therefore, when driven by an external tool, MUST be driven
with an Open Drain gate. Failure to do so might result in
permanent damage to the MSC8101 and / or to ADS logic.
I.P.U.
Interrupt Request 5. Connected to MSC8101's DP5/IRQ5b/
DREQ5 signal. Pulled up on the ADS with a 10 KΩ resistor. This
line is shared with the Fast Ethernet transceiver's interrupt line
and therefore, when driven by an external tool, MUST be driven
with an Open Drain gate. Failure to do so might result in
permanent damage to the MSC8101 and / or to ADS logic.
MSC8101ADS RevB User's Manual
For More Information On This Product,
Go to: www.freescale.com
Description
a
:15). This is a double buffered version of the
MOTOROLA

Advertisement

Table of Contents
loading

Table of Contents