In Case Of Difficulty - Honeywell PRO TH3210D Manual

Non-programmable digital thermostat
Hide thumbs Also See for PRO TH3210D:
Table of Contents

Advertisement

Installation
Guide
Ill you have difficult}, with your thermostat,
please try the suggestions
below. Most
problems
can be corrected
quickly and easily.
Display is blank
Temperature
se_ings
do not
change
Check circuit breaker and reset if necessary.
Make sure heating & cooling power switches are on.
o
Make sure equipment
door is securely
closed.
If battery powered,
make sure fresh AA alkaline batteries are installed.
Make sure heating and cooling
temperatures
are set to acceptable
ranges:
Heat: 40 ° to 90°F (4.5 ° to 32°C).
o
Cool: 50 ° to 99°F (10 ° to 37°C).
Heating system
o
does not respond
("Heat On"
appears on
o
Stiffen)
Cooling system
does net respond
("Cool On"
appears on
Stiffen)
_'CooJ Orl" or
"Heat On"
is flashing
o
®
®
o
Check for 24 Vac at the equipment
on the secondary
side of the trans-
former between
power and common.
If voltage
is not present, check the
heating equipment
to find the cause of the problem.
Check for 24 Vac between the heat terminal
(Y) and the transformer
common.
If 24 Vac is present, the thermostat
is functional.
Check the
heating equipment
to find the cause of the problem.
Check for loose or broken wires between
the thermostat
and the heating
equipment.
Check for 24 Vac at the equipment
on the secondary
side of the trans-
former between
power and common.
If voltage
is not present, check the
cooling equipment
to find the cause of the problem
Check for 24 Vac between the cooling terminal
(Y) and the transformer
common.
If 24 Vac is present, the thermostat
is functional.
Check the
cooling system to find the cause of the problem.
Check for loose or broken wires between
the thermostat
and the cooling
equipment.
Compressor
protection
timeout is engaged. Wait 5 minutes for the
system to restart safely, without
damage
to the compressor.
"Heat
On" is
o
Set the System switch
to Heat, and set the temperature
level above the
not displayed
current room temperature.
"Ceel
On" is
o
Set the System switch
to Cool, and set the temperature
level below the
net displayed
current room temperature.
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents