HE220A,B AND HE260A,B BYPASS FLOW-THROUGH HUMIDIFIER

SPECIFICATIONS

Capacity:
At 120°F (49°C) plenum temperature and 0.20 static
pressure drop across supply and return:
HE220A,B: 12 gallons per day (gpd) or 46 liters per day
(lpd).
HE260A,B: 17 gallons per day (gpd) or 65 liters per day
(lpd).
Humidified Area:
See Table 1.
Electrical Ratings:
24 Vac, 60 Hz, 0.5A.
Humidifier Pad Dimensions:
See Table 2.
House Description
Loose
Average
Tight
Table 2. Dimensions Of Humidifier Pads In In. (mm).
Model
Height
HE220
9-13/16 (249)
HE260
13 (330)
Table 3. Dimensions Of Plenum Opening In In. (mm).
Model
Height
HE220
9-7/16 (241)
HE260
12-5/8 (321)

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1.
Your local Home and Building Control Sales Office (check white pages of your phone directory).
2.
Home and Building Control Customer Logistics
Honeywell Inc., 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386 (612) 951-1000
In Canada—Honeywell Limited/Honeywell Limitée, 155 Gordon Baker Road, North York, Ontario M2H 3N7.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0191—3
Table 1. Size Of Area That Can Be Humidified.
Air Changes Per Hour
Two
One
One-half
Width
Depth
9-1/2 (241)
1-1/2 (38)
10 (254)
1-1/2 (38)
Width
9-5/16 (238)
9-3/4 (248)
Plenum Opening Dimensions (Height x Width):
See Table 3.
Summer Shut-off Damper Dimensions (Height x Width):
See Table 4.
Bypass Duct Opening (Diameter):
6 in. (152 mm).
Drain Connection:
1/2 in. (13 mm) I.D. plastic hose connected directly to drain
fitting on unit.
Dimensions:
Refer to Fig. 1 and 2.
HE220 Area (Up To)
Sq ft
Sq m
750
70
1,500
140
3,000
280
Table 4. Dimensions Of Summer Shut-off Damper
In In. (mm).
Model
HE220
9-3/16 (234)
HE260
12-3/8 (314)
2
HE260 Area (Up To)
Sq ft
Sq m
1,000
93
2,000
186
4,000
372
Height
Width
8-7/8 (226)
9-5/16 (236)