Before c alling forservice, trythesuggestions
below toseewhether youcan solve your
problem
without
outside
help.
CHECK POINT
SOLUTIONS
PROBLEMS
Dehumidifier
does not
work when pressing
the POWER
ON
button.
Dehumidifier
is
operating,
but the
dehumidification
function
does not
work.
Loud noise and/
or vibration
during
operation.
Sounds.
Is the power cord plugged into
a grounded
3-prong
outlet?
Is BUCKET
FULL light on?
Does BUCKET
FULL light
appear after emptying
the
water bucket?
Is the compressor
running
as
well as the fan?
Is there frost on the coils?
Is the unit on a level surface?
Sounds like flowing water
during
and after operation.
It makes a pinging
sound.
Plug the power cord securely
into a
grounded
3-prong outlet.
Empty the water bucket
and
re-install.
Check the float switch
to make sure
it is free and not obstructed.
The unit may be in the defrost
mode. The fan is running
but not the
compressor.
The unit will return to
dehumidification
automatically.
Move the unit to a level surface.
Dehumidification
Are the filters and grills dirty?
function
is inefficient
Is indoor temperature
under
65°F?
Unit is discharging
Normal:
Compressor
and electric
warm air.
motor discharge
nominal
heat.
Water does not drain
Re-install
drain hose according
through hose.
to this manual.
Check the DRAIN CONNEC-
TOR. Is it installed correctly?
Check the drain hose for
kinks or obstructions.
Is PUMP light on?
Check the DRAIN CON-
NECTOR
making
sure it is
installed securely.
Check the garden
hose for
tangles
or folds.
Water does not drain
through garden hose.
Water does not drain
through pump drain
hose.
Check the connecting
hose
for tangles
or folds.
Does pump display light
appear?
This is the normal
sound of the
refrigerant
flowing through the coils.
Normal
sound of expansion
and
contraction
caused
by temperature
changes.
Clean the SIDE GRILL and AtR
FILTER.
Unit does not operate efficiently
below 65°F.
Flatten the hose or remove
block-
age.
Turn on the pump.
Re-install it according to this manual.
Flatten the hose or remove
block-
age.
Re-install
drain hose according
to
this manual.
Flatten the hose or remove blockage.
Turn on the pump.
10