Network Controller Modules Supported
The following VMEbus network controller modules are supported by the
MVME166Bug. The default address for each type and position is showed to
indicate where the controller must reside to be supported by the
MVME166Bug. The controllers are accessed via the specified CLUN and
DLUNs listed here. The CLUN and DLUNs are used in conjunction with the
debugger commands NBH, NBO, NIOP, NIOC, NIOT, NPING, and NAB,
and also with the debugger system calls .NETRD, .NETWR, .NETFOPN,
.NETFRD, .NETCFIG, and .NETCTRL.
Controller
Type
MVME166
MVME376
MVME376
MVME376
MVME376
MVME376
MVME376
MVME374
MVME374
MVME374
MVME374
MVME374
MVME374
MVME166IG/D2C-1
NETWORK CONTROLLER
CLUN
DLUN
$00
$00
$02
$00
$03
$00
$04
$00
$05
$00
$06
$00
$07
$00
$10
$00
$11
$00
$12
$00
$13
$00
$14
$00
$15
$00
DATA
Interface
Address
Type
$FFF46000
Ethernet
$FFFF1200
Ethernet
$FFFF1400
Ethernet
$FFFF1600
Ethernet
$FFFF5400
Ethernet
$FFFF5600
Ethernet
$FFFFA400
Ethernet
$FF000000
Ethernet
$FF100000
Ethernet
$FF200000
Ethernet
$FF300000
Ethernet
$FF400000
Ethernet
$FF500000
Ethernet
C