Mx3Plus Desk Top Cradle/Mx3Plus Power Supply, External, Ac; Us Ac To Dc Adapter Specifications - Honeywell MX3Plus Cradle Reference Manual

Hide thumbs Also See for MX3Plus:
Table of Contents

Advertisement

MX3Plus Desk Top Cradle/MX3Plus Power Supply, External, AC

Honeywell offers two types of external power supplies for the MX3Plus desk top cradle:
The external power supply may be connected to either a 120V, 60Hz supply or, outside North America, to a 230V, 50Hz
supply, using the appropriate detachable cord set.
In both cases, connect the external AC supply to a properly grounded source of supply provided with maximum 15 Amp over
current protection (10 Amp for 230V circuits).
1. Insert the barrel connector into the desk top cradle power jack (located on the back of the cradle) and push in firmly.
2. When a docked MX3Plus is receiving power from a cradle, the cradle Status LED is green and the CHGR LED on the
mobile device are illuminated.

US AC to DC Adapter Specifications

Feature
Input Power Switch
Power "ON" Indicator
Input Fusing
Input Voltage
Input Frequency
Input Connector
Output Connector
Output Voltage
Output Current
Operating Temperature
Storage Temperature
Humidity
Specification
None
None
Thermal Fuse
108VAC min - 132VAC max
47 - 63 Hz
North American wall plug, no ground
Barrel connector, female, 5.5 x 2.5 x 11.5mm, Center Positive
+12VDC, unregulated
0 Amps min, 1.5 Amps max
32° F to 104° F
0° C to 40° C
-13° F to 158° F
-25° C to 70° C
Operates in a relative humidity of:
5 – 95% (non-condensing)
2-9