Electrical Adjustment
Grp / No.
Item
15
Filter 2nd Cartridge Scroll Factor 6
16
Filter 2nd Cartridge Scroll Factor 7
17
Filter 2nd Cartridge Scroll Factor 8
18
Filter 2nd Cartridge Scroll Factor 9
19
Filter 2nd Cartridge Scroll Factor 10
20
Filter 3rd Cartridge Scroll Factor 1
21
Filter 3rd Cartridge Scroll Factor 2
22
Filter 3rd Cartridge Scroll Factor 3
23
Filter 3rd Cartridge Scroll Factor 4
24
Filter 3rd Cartridge Scroll Factor 5
25
Filter 3rd Cartridge Scroll Factor 6
26
Filter 3rd Cartridge Scroll Factor 7
27
Filter 3rd Cartridge Scroll Factor 8
28
Filter 3rd Cartridge Scroll Factor 9
29
Filter 3rd Cartridge Scroll Factor 10
250
Fan Voltage Adjustment
0
Fan 1 Min Adjust (DAC)
1
Fan 1 Max Adjust (DAC)
2
Fan 2 Min Adjust (DAC)
3
Fan 2 Max Adjust (DAC)
4
Fan 3 Min Adjust (DAC)
5
Fan 3 Max Adjust (DAC)
6
Fan 4 Min Adjust (DAC)
7
Fan 4 Max Adjust (DAC)
8
Fan 5 Min Adjust (DAC)
9
Fan 5 Max Adjust (DAC)
10
Fan 6 Adjust (DAC)
11
Fan 7 Adjust (DAC)
12
Fan 8 Adjust (DAC)
252
Fan Option
1
Safety Switch
2
Fan Manual Switch
3
Fan1 Manual Voltage
4
Fan2 Manual Voltage
5
Fan3 Manual Voltage
6
Fan4 Manual Voltage
7
Fan5 Manual Voltage
8
Fan6-8 Manual Voltage
9
All Fan Max Min Control
10
Press Data
253
Fan Temp Error Setting
0
Temp A Warning (High)
1
Temp B Warning (High)
2
Temp C Warning (High)
3
Temp B-A Warning (High)
4
Temp C-A Warning (High)
5
Temp A Warning (Normal)
6
Temp B Warning (Normal)
7
Temp C Warning (Normal)
8
Temp B-A Warning (Normal)
9
Temp C-A Warning (Normal)
10
Temp A Warning (Eco)
11
Temp B Warning (Eco)
12
Temp C Warning (Eco)
13
Temp B-A Warning (Eco)
14
Temp C-A Warning (Eco)
Function
3rd Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
Safety Application use
Fan Manual SW (0: Auto 1: Manual)
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
Forced mode of Lamp mode - Fan Control.
0: Normal, 1: High-MIN, 2: High-MAX, 3: Normal-MIN, 4:
Normal-MAX, 5: Eco1-MIN, 6: Eco1-MAX, 7: Eco2-MIN, 8: Eco2-
MAX
Air Pressure Data (Read only)
(Memorized)
Temp A (Room) to judge the Temp Error at High
Temp B (Lamp) to judge the Temp Error at High
Temp C (Panel) to judge the Temp Error at High
Temp B - A (Filter Clogged) to judge the Temp Error at High
Temp C - A (Filter Clogged) to judge the Temp Error at High
Temp A (Room) to judge the Temp Error at Normal
Temp B (Lamp) to judge the Temp Error at Normal
Temp C (Panel) to judge the Temp Error at Normal
Temp B - A (Filter Clogged) to judge the Temp Error at Normal
Temp C - A (Filter Clogged) to judge the Temp Error at Normal
Temp A (Room) to judge the Temp Error at Eco
Temp B (Lamp) to judge the Temp Error at Eco
Temp C (Panel) to judge the Temp Error at Eco
Temp B - A (Filter Clogged) to judge the Temp Error at Eco
Temp C - A (Filter Clogged) to judge the Temp Error at Eco
Range
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-6
0-1
0-255
0-255
0-255
0-255
0-255
0-255
0 - 8
-
110°
70°
L1
L4
L3
Ceiling
Normal
L2
-70°
-110°
Normal
30-100
30-100
30-100
0-100
0-100
30-100
30-100
30-100
0-100
0-100
30-100
30-100
30-100
0-100
0-100
-66-
Initial
Note
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
32
* Fan voltage adj.
240
* Fan voltage adj.
32
* Fan voltage adj.
240
* Fan voltage adj.
32
* Fan voltage adj.
240
* Fan voltage adj.
35
* Fan voltage adj.
230
* Fan voltage adj.
35
* Fan voltage adj.
230
* Fan voltage adj.
190
* Fan voltage adj.
190
* Fan voltage adj.
190
* Fan voltage adj.
0
0
100
100
100
100
100
100
0
-
Slant
Off
L1
L2
Ceiling
Off
Normal
Up
Down
On
Ceiling
Up
Down
Definition of Slant
180°
Off
-70° ~ 70°
L1
70° ~ 110°
L2
-70° ~ -110°
L3
-70° ~ 70°
L4
110° ~ -110°
Ceiling
Top
Bottom
51
51
51
51
64
64
64
64
59
59
59
59
100
100
100
100
100
100
100
100
51
51
51
51
64
64
64
64
59
59
59
59
100
100
100
100
100
100
100
100
51
51
51
51
64
64
64
64
59
59
59
59
100
100
100
100
100
100
100
100
L3
L4
Normal
Ceiling
Normal
Ceiling

Advertisement