Sanyo PLC-XTC50L Service Manual page 63

Hide thumbs Also See for PLC-XTC50L:
Table of Contents

Advertisement

Electrical Adjustment
Grp / No.
Item
1
VREF_R
2
VREF_G
3
VREF_B
200
Option
0
Logo Display Prohibition
1
RS232C Baud rate
3
Shipping Set
4
CABLE SW
5
PW Debug Command Enable
6
Device Refresh Disable
8
PJ-NET Hung up check
20
21
Lamp Warning Time (NORMAL)
22
Lamp Warning Time (ECO)
23
Lamp Warning Time (HIGH)
50
Lamp Replacement Display
51
Filter Warning Display
52
Lamp Counter Reset Times
53
Filter Counter Reset Times
54
Factory Default Executed Times
55
Motor Operation Stop
56
Menu Position (X)
57
Menu Position (Y)
58
Lamp Go Out
70
ADC Device Select for Analog PC 0 = ISL51002, 1 = PW392 AFE
71
ADC Device Select for Component 0 = ISL51002, 1 = PW392 AFE
80
Destination
100 Disable Auto Picture Control
201
Option (Signal) Not Used
0
FrameLock Option
1
Dither Enable
204
Simulation mode
0
PW392C Enable
1
PW610 Enable
210
Lamp Contorl
0
Dimmer SW
1
Manual Control
2
DIMMER_CTRL_LEVEL1
3
DIMMER_CTRL_LEVEL2
4
DIMMER_CTRL_LEVEL3
5
DIMMER_CTRL_LEVEL4
6
DIMMER_CTRL_LEVEL5
7
DIMMER_CTRL_LEVEL6
8
DIMMER_CTRL_LEVEL7
9
DIMMER_CTRL_LEVEL8
10
DIMMER_CTRL_LEVEL9
11
DIMMER_CTRL_LEVEL10
12
DIMMER_CTRL_LEVEL11
13
DIMMER_CTRL_LEVEL12
14
DIMMER_CTRL_LEVEL13
15
DIMMER_CTRL_LEVEL14
16
DIMMER_CTRL_LEVEL15
17
DIMMER_AVERAGE_POINT
18
DIMMER_AVERAGE_DATA
19
DIMMER_LEVEL_AUTO
20
DIMMER_LEVEL_NORMAL
21
DIMMER_LEVEL_ECO
23
VOLTAGE_LEVEL
24
DIMMER_LEVEL_HIGH
220
Projector Error Log
0
Warning_Log_1
:
:
49
Warning_Log_50
Function
0:Menu 1:Forced
0: 19200bps 1: 9600bps
Shipping set when the value is set to 10
Long Cable 0: Disable 1: Enable
0: Disable (Sanyo Serial Command Enable)
1: Enable (PW Debug Mode)
0: Enable 1: Disable
0: Enable 1: Disable
1:On 0:Off
1:On 0:Off
Read only
Read only
Read only
0: Enable 1: Disable
X Offset
Y Offset
Lamp goes out
Language Set at Shipping 0:English 1:Japanese
0 : Normal operation 1 : Auto Picture Control Off
Frame Lock Setting 0: Normal(Auto) 1: OFF
0: Disable 1: Enable
0: Off, 1: On
0: Off, 1: On
0:Auto 1:Manual
Lamp Power Manual Control (DIMMER_CTRL_LEVEL
0(Dark)~15(Bright))
Y Level1 Data for Dimmer
Y Level2 Data for Dimmer
Y Level3 Data for Dimmer
Y Level4 Data for Dimmer
Y Level5 Data for Dimmer
Y Level6 Data for Dimmer
Y Level7 Data for Dimmer
Y Level8 Data for Dimmer
Y Level9 Data for Dimmer
Y Level10 Data for Dimmer
Y Level11 Data for Dimmer
Y Level12 Data for Dimmer
Y Level13 Data for Dimmer
Y Level14 Data for Dimmer
Y Level15 Data for Dimmer
Y Average Point
Y Average Data (Read only)
Current Y Level (Read only)
Dim Level at Normal
Dim Level at Eco
Lamp Voltage (Read only)
Dim Level at High
Latest Error log
:
50th Error log
Range
0 - 255
0 - 255
0 - 255
0 - 1
0 - 1
0 - 20
0 - 1
0 - 1
0 - 1
0 - 1
0 - 10
1-16
1-16
1-16
0 - 1
0 - 1
0 - 255
0 - 255
0 - 255
0 - 1
0 - 1024
0-1024
0 - 1
0 - 1
0 - 1
0 - 1
0-1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 15
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1 - 16
-
-
0 - 15
0 - 15
-
0 - 15
0 - 32767
:
0 - 32767
-63-
Initial
Note
234
* Video center
234
* Vide center
234
0
0
0
0
0
0
0
0
5
6
4
1
1
0
0
0
0
0
0
0
0
1
0
Initial: 1 Shipping 0
0
0
0
0
0
0
7
14
21
28
35
42
49
56
63
70
77
84
91
98
105
4
-
-
8
0
-
15
0
:
0

Advertisement