Serial daisy chain position
Set the first and last terminals in the chain when the
SERIAL IN/OUT terminal of this unit is connected using
a daisy chain scheme.
[---]:
When controlling this unit alone wi h serial control,
or connecting at a position other than the first and
last terminals in a daisy chain
[Top]:
When connecting at the first terminal in a daisy
chain
[End]:
When connecting at the last terminal in a daisy
chain
LAN control protocol
Select the LAN control protocol.
[Protocol 1]:
Control with the Panasonic Display sequence.
[Protocol 2]:
Control with the sequence that compatible with
Panasonic Projector.
Note
For PJLink and WEB browser control, the operation is
possible regardless of the setting.
When performing the command control with TCP/IP,
select [Protocol 1].
When operating the "Early Warning Software" or
"Multi Monitoring & Control Software", select [Protocol
2].
66
English

Information timing

Set up the informing manner for no signal or
temperature rising.
During RS-232C controls:
Warning or error message sent on the display
automatically.
During LAN controls:
Acquire the warning or error message from the
display.
1
Select the item with
Select the set point with
Information timing
No signal warning
No signal warning timing
No signal error
No signal error timing
Temperature warning
[No signal warning]
When set to [On], the display sends out the no signal
warning.
[No signal warning timing]
Set up the detecting time for no signal warning.
(Range: 01 - 60, Interval: 1 minute)
[No signal error]
When set to [On], the display sends out the no signal
error.
[No signal error timing]
Set up the detecting time for no signal error.
(Range: 01 - 90, Interval: 1 minute)
The warning of [No signal warning] and the error
of [No signal error] are not sent when the no signal
state is detected through any of the following
func ions:
[No signal power off], [HDMI1 power
management], [HDMI2 power management],
[DIGITAL LINK power management]*, [DVI-D
power management], [PC power management]
(see page 47)
: LF80 series only
*
If there is no signal when [PC IN] is input, [PC
power management] is activated first and the
Display enters the standby mode.
Setting Example:
[No signal warning timing]: 5 minutes
[No signal error timing]: 10 minutes
[PC power management]: [On] (60 seconds)
Note
The [No signal error timing] cannot be set shorter
than [No signal warning timing].
.
.
On
5min
On
10min
On

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-55lf8wTh-42lf8wTh-42lf80wTh-49lf80wTh-55lf80w