GE PGP9830 Owner's Manual & Installation Instructions page 20

Gas downdraft
Table of Contents

Advertisement

Available languages

Available languages

Z
O
i
I-.
U
=)
!-.
Z
u
Z
O
g
_u
_u
Z
i
Installation
Instructions
CABINET PREPARATION
ITI PREPARING FOR INSTALLATION
Positioning
the cooktop
The cooktop is designed to look best when centered in a
cabinet at least 50"wide.
The exhaust vent beneath the cooktop must be located
between wall studs or floor joists so that the ductwork may
be installed properly.
13" max:-- _L-I
depth of
___._,
unprotected I
IJ
I
overhead
I
II
I
cabinets
I
"'^
,
'
I 4u" mln. clearance
/from
countertop
/
to unprotected
_" overhead surface
18" min. height
from countertop
to
nearest cabinet
on
either side of the unit
5" min. clearance
from cutout to
side walls
The downdraft system with blower, motor and ductwork will
occupy the cabinet below the cooktop. Drawers cannot be
installed below this cooktop.
Avoid placing cabinets above the cooktop unit, if possible,
in order to reduce the hazards caused by reaching over
heated surface units.
If the cabinetry is used above the cooktop, allow a minimum
30" clearance between the cooking surface and the bottom
of the unprotected cabinet.
If the clearance between the cooktop and the cabinetry is
lessthan 30", the cabinet bottom must be protected with
a flame retardant millboard at least 1/4"thick, or gypsum
board at least s/16" t hick, covered with 28 gauge sheet steel
or 0.020" thick copper. Clearance between the cooktop and
the protected cabinetry MUSTNEVERBE LESS THAN 24".
EXCEPTION: Installation of a listed microwave oven or
cooking appliance over the cooktop shall conform to the
installation instructions packed with that appliance.
Working areas adjacent to the cooktop should have an
18" minimum clearance between the countertop and the
bottom of the cabinet. If the clearance is less than 18", the
adjacent cabinets should be at least 5" from the side edge
of the cooktop.
[_ PREPARING THE BASE CABINET
This cooktop is designed to fit easily into a variety of
cabinets. However, the combined installation of a downdraft
vent and a cooktop require careful consideration.
Some cabinets may require modifications.
i This installation requires a 24" min. deep cabinet base.
The cabinet must be at least 30" wide.
Preparing a cabinet that is against a wall
In some cabinets, the sides may need to be scooped or cut
down 5sA " as shown, and the corner braces removed in
order to accommodate the unit.
In 75 cm and 90 cm frameless European cabinets,
the back panel may need to be cut down 5sA " to
accommodate the unit.
Preparing a peninsula or island-type cabinet
In a peninsula or island type cabinet, the sides may need to
be scooped or cut down, and the corner braces removed in
order to accommodate the unit.
5%"
Approx.
5:Y_ ' Approx.
for European
cabinets
0
49
80516
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pgp989

Table of Contents