FIP-1. 14 010-317 Reseat Fuser
Step
Possible causative parts:
FUSER ASSY (PL6.1.1)
PWBA MCU (PL10.7.7)
HARN ASSY FUSER (PL10.8.6)
Checking after reseating the FUSER ASSY
Reseat the FUSER ASSY.
Warning: Start the operation after the FUSER ASSY has
1
cooled down.
Does the error still occur when the power is turned OFF and
ON?
Checking the connectors for connection
Remove the FUSER ASSY.
Warning: Start the operation after the FUSER ASSY has
cooled down.
Check the connections between the PWBA MCU and
FUSER ASSY.
Are P/J17 and P/J171 connected correctly?
2
Does the error still occur when the power is turned OFF and
3
ON?
Checking the HARN ASSY FUSER for continuity
Remove the FUSER ASSY.
Warning: Start the operation after the FUSER ASSY has
4
cooled down.
Disconnect J17 from the PWBA MCU.
Is each cable of J17 <=> P171 continuous?
NOTE: P171 is attached to the frame.
Version 1 2008.02.01
Check
1 - 239
Chapter 1 Troubleshooting
Remedy
Yes
Go to step 2.
End of work.
Reconnect the
connector(s) P/
Go to step 4.
J17 and/or P/J171
correctly, then go
to step 3.
Go to step 4.
End of work.
Replace the
Go to step 5.
HARN ASSY
FUSER.
No