144 en | Connection
6.24
PRS-NSP Network Splitter
Optical network
Connect the network splitter to the optical network with the optical network sockets.
Figure 6.49 Optical network
NOTICE!
If the distance between two devices is less than 100 m, use a network splitter between
devices to remove the use of fiber interfaces. Use only the trunk sockets of the network
splitter in this case.
Power supply
You can connect an external power supply to the external power supply socket of the network
splitter. The network splitter is supplied with a Kycon KPP-4P plug, which you can connect to
this socket. The external power supply only supplies power to the connected tap-offs.
Figure 6.50 Kycon KPP-4P plug, connection
Pin
1
2
3
4
Table 6.29 Kycon KPP-4P plug, connection
NOTICE!
You can, for example, connect a DCN-EPS Extension Power Supply to the Kycon KPP-4P
socket of the network splitter.
DCN-NG_IOM_V4.1 | V1.3 | 2012.07
tap-off 1
trunk
2
3
7
8
tap-off 2
trunk
Signal
Ground
Power from the external power supply.
Voltage: 24 - 48 V, max. 5 A.
Power from the system. Voltage:48 V, max.
5 A.
Not connected