14.12 Environment And Material - Siemens SIMATIC FS600 Instruction Manual

Table of Contents

Advertisement

14.12 Environment and Material

Protection type
Operating temperature
Storage temperature
Humidity
Dimensions
Distance from the middle of the
scanning plane to the bottom
edge of the housing
Distance from front edge of the
housing to the axis of the rotating
mirror
Connection
Control cable length X1
Data cable length X2
RS 232
Data cable length X2
RS 422
Housing
Weight
Dynamic stress across
3 axles
Continuous shock across 3 axes In accordance with IEC 60068 Part 2 - 29, 10 G,
Interference immunity
Rotating mirror drive
Rotating mirror bearing
Table 14.12-1: Technical Data on the Environment and Material
IP 65 in accordance with IEC 60529
0 ... + 50 °C
-20 °C ... + 60 °C
DIN 40040 Table 10, Identifying letter E
(moderately dry)
140 x 155 x 135 (W x H x D) in mm
48.75 mm
64 mm
2 connectors (plugged in from above)
Max. 50 m at a cable cross-section of 0.5 mm
shielded
Connect shield with PE to the electronics cabinet
only
Max. 10 m
Max. 50 m (twisted pair)
Die-cast aluminum, plastic
Approx. 2 kg
In accordance with IEC 60068 Part 2 - 6, 10 –
150 Hz, max. 5 G
16 ms
In accordance with DIN EN 61496-1
(corresponds to
requirements for type 4); additionally in
accordance with
DIN 40839-1/3 test pulses 1, 2, 3a, 3b and 5 (not
used for vehicles with internal combustion
engines)
Brushless direct-current motor
Maintenance-free ball bearing
2
,