Mds600 And D6000 Dual Domain, High-Performance Cabling - HP 634041-006 Deployment Manual

Solutions with 6gb sas bl switches and external sas storage enclosures
Table of Contents

Advertisement

MDS600 and D6000 dual domain, high-performance cabling

This example illustrates cabling for an optimal high-performance, high-availability configuration
in dual domain configurations. In this configuration, note the following:
An additional cable from each I/O module to an adjacent port on the switch offers additional
performance: one cable provides a 4x connection; two cables provide a 8x (high-performance)
connection. For more information on switch ports, 4x, and 8x (high-performance) cabling,
see
"HP 6Gb SAS BL Switch" (page
IMPORTANT:
I/O module must connect to one of the following pairs of switch ports: 1/2, 3/4, 5/6, or 7/8.
NOTE:
Restrictions exist, depending on the controller, storage enclosure, and drive model. For
more information, see
(page 77)
90
Deployment examples
When using high-performance cabling, both cables from an MDS600 or D6000
"External SAS device, controller, drive, and cabling support matrices"
20).
Devices and quantities
MDS600/D6000 storage enclosures: 1
I/O modules: 4
BladeSystem c7000 enclosures: 1
6Gb SAS BL Switches: 2
Server blade types: half-height and full-height
Connection details
Switch in interconnect bay 5:
Switch in interconnect bay 6:
Port 1: to storage drawer 2, primary
I/O module, port 1
Port 2: to storage drawer 2, primary
I/O module, port 2
Port 5: to storage drawer 1, primary
I/O module, port 1
Port 6: to storage drawer 1, primary
I/O module, port 2
Port 1: to storage drawer 2, secondary
I/O module, port 1
Port 2: to storage drawer 2, secondary
I/O module, port 2
Port 5: to storage drawer 1, secondary
I/O module, port 1
Port 6: to storage drawer 1, secondary
I/O module, port 2