INSTALLATION
• To reduce the possibility of gas leaks, apply
Teflon tape or a thread compound approved for
use with LP or natural gases to all threaded
connections.
• Flexible metal appliance connector (5/8" I.D.) A 3-
foot length is recommended for ease of
installation but other lengths are acceptable.
Dimensions and Clearances
Provide enough clearance between the cooktop and adjacent combustible surfaces. These dimensions
must be met for safe use of your cooktop. The location of the electrical outlet and pipe opening may be
adjusted to meet specific requirements.
The cooktop must be placed with at least 3 3/8" of clearance to the back wall.
Make sure wall coverings, countertop and cabinets around cooktop can withstand the heat (up to 194
a
℉) generated by the cooktop
To ensure accuracy, it is best to make a template when cutting the opening in the counter
b
-
A
Width of upper plate
B
Depth of upper plate
C
Height of cooktop base
D
Width of cooktop base
E
Depth of cooktop base
F
Width of cutout
G
Depth of cutout
H
Distance from cutout to side wall on the left of unit. / Distance from
cutout to side wall on the right of the unit.
I
Distance from front edge of cutout to front edge of countertop
Never use an old connector when installing a
new cooktop.
• Flare union adapter for connection to gas supply
line (3/4" or 1/2" NPT x 5/8" I.D.)
• Flare union adapter for connection to pressure
regulator on cooktop. (1/4" NPT x 1/2" I.D.)
• Liquid leak detector or soapy water
Dimension/Clearance
CBGD2414S
23 3/8" (594 mm)
20 1/4" (514 mm)
1 9/16" (40 mm)
21 5/8" (550 mm)
18 1/2" (470 mm)
22 1/8" (562 mm)
18 57/64" (480 mm)
2
11 13/16" (300 mm)
2" (51 mm)
2