en | Configuration
12
13
14
15
Notice!
When the programming data exceeds the display range of the LED/LCD number indicators,
there will be no display on the keypad.
7.2

PC Programming

Notice!
Support of firmware version 1.4 or higher!
This manual describes the configuration with the A-Link Plus software in connection with the
firmware version 1.4 or higher. If you use an older firmware version, contact your local sales
contact.
The AMAX panel supports remote programming via USB, telephone, or IP network using the
software A-Link Plus. The following option can be performed:
Common settings for all types of connections
1.
2.
Control Panel Type
4
Subscriber Number
1.
2.
3.
2015.05 | 06 | F.01U.309.277
All manuals and user guides at all-guides.com
X
Setting the date and time
Uploading / downloading programming parameters
Remote arming / disarming of each area
Enabling / disabling the alarm siren of each area
Enabling / disabling each output
Select Customer –Open Customer from the menu bar of the A-Link Plus program.
The Customer Information index sheet opens.
Select the Control Panel Configuration index sheet.
Select the control panel type.
Select the item Communication and Report manager – Receiver setting in the same
index sheet.
Make sure that the value for subscriber number 1 is the same as currently programmed in
AMAX panel as receiver 1.
The value is 000000, when the firmware of the AMAX panel was upgraded or when the
AMAX panel has factory settings.
Installation Manual
X
X
X
AMAX panel
X
X
X
X