CHAPTER 7 FEATURES RELATED TO MAINTENANCE AND
FAILURE ANALYSIS
7.1 Notifying the Cause of the STOP Error Code
7.1.1 Overview
This equipment records the memory contents in memory dump files when the system is
forcibly recovered from OS lockup, an NMI is generated due to hardware failure, or
uncorrectable memory error occurs. At the same time, a blue screen appears and an
identifier (NMI_HARDWARE_FAILURE) is displayed.
Additionally, the digital LED status display mounted on the equipment displays the STOP
error code 0x80.
This function detects a blue screen caused by an error with the STOP error code 0x80 and
records the cause of the blue screen in the event log after restart this equipment.
NOTE
• These causes may not be recordable in the event log if you perform an action
(for example, shutdown) that aborts the process of the STOP error code
cause analysis.
In the case of a 8GB memory dump file, analysis of the STOP error code
takes about six minutes.
7. FEATURES RELATED TO MAINTENANCE AND FAILURE ANALYSIS
7-1