Siemens SINAMICS G130 Function Manual page 98

Chassis, cabinet modules
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

Controlling the safety functions
5.4 Activating "SBC" via the Safe Brake Adapter
Table 5- 32
Terminal strip -X15, fast de-energization
Connection
Signal
-X15.1
AUX1
-X15.2
AUX2
Max. connectable cross-section 2.5 mm
Spare fuse
The type of spare fuse is as follows: 2 A, time-lag.
Note
Correctly mounting the housing cover after replacing a fuse
An adhesive label is provided on the housing cover indicating the position of the connector.
Mount the cover in the correct position so that the inscription of the label matches the actual
connectors.
Mounting
The Safe Brake Adapter is designed for mounting on a rail according to IEC 60715.
The dimensions are shown in the following dimension drawing.
Figure 5-11
96
Description
Supply voltage: 230 V AC
Current consumption: 2 A
2
Dimension drawing of the Safe Brake Adapter (data in mm)
Safety Integrated
Function Manual, 08/2023, A5E03264275A