Gas installation
This range was designed for use with NG and LPG
gas. Always use a pressure regulator exclusive for
your gas range. The lack of pressure regulator might
cause excess of pressure and leak of gas.
Always check for the validity of the pressure regulator.
Hose and regulator should be replaced every 5 years.
Technical specification of the pressure regulator.
• Pressure : NG 2.0 kPa, LPG 2.9 kPa
Flexible hose
If you use flexible hoses, make sure that:
• the hoses do not become trapped or squashed.
• the hoses are not subject to twisting or pulling forces.
• the hoses do not come into contact with sharp
edges or cutting edges.
• Does not go on the back of the gas range neither
close to the hot air exits.
• the hoses do not come into contact with parts that
could reach a temperature higher than 70 °C above
room temperature.
• After the installation, check if there is any gas leak,
using soap or liquid detergent foam.
Ensure that the full length of the hoses are accessible
for inspection.
WARNING
• DO NOT USE PLASTIC PIPE
TO CONNECT GAS COOKER
BECAUSE THEY CAN CAUSE
A LEAKAGE. THE USE OF
METAL FLEXIBLE PIPES TO
CONNECT HOME APPLIANCES
IS RECOMMENDED.
Safety valve
The installation of a safety valve for opening and
closing the gas supply is a compulsory requirement.
Fit the safety valve between the gas connecting
line to the appropriate room and the cooker. Ensure
unhindered access to this valve.
Checking for leaks
After connecting the gas line, check the connections
for leaks using soapy water.
Initial use
Switch the appliance on as described in the
instruction manual.
Light all the burners and check that the flames remain
stable at both the high and low settings.
Check ignition of surface
burners
Electric ignition
Push knob when igniting surface burners and make
sure they have ignited. You will hear a clicking sound
indicating proper operation of the spark module.
Once the air has been purged from the supply lines,
burner should ignite within 4 seconds. After burner
ignites, turn knob to its original position. Try each
burner consecutively until all burners have been
checked.
In the event of the burner flames being accidentally
extinguished, turn off burner control and do not
attempt to re-ignite the burner for at least 1 min.
The device shall not be operated for more than 15 s.
If after 15 s the burner has not lit, stop operating the
device and open the compartment door and/or wait at
least 1 min before attempting a further ignition of the
burner.
Quality of flame
The combustion of burner flames must be confirmed
visually.
A Yellow flames - Needs
maintenance.
B Yellow tips on outer cones -
It is normal for LP gas
C Soft blue flames - It is normal for
natural gas.
NOTE
• With LP gas, some yellow tipping on outer
cones is normal.
INSTALLATION
17