Sony DSC-WX50 Service Manual page 15

Hide thumbs Also See for DSC-WX50:
Table of Contents

Advertisement

Ver. 1.2 2012.03
The changed portions from
Ver. 1.1 are shown in blue.
1-10.
TWO TUBE LUBRICATING BLOCK ASSY AND GROUP 1 FRAME REPLACING METHOD
Removal
Disengage the two claws and remove the FG Leaf Spring.
1
Remove the two Sensors.
2
Disengage the three claws and remove the FPC Retainer.
3
Sensor
Claws
FG Leaf
Spring
Sensor
Remove the LF-115 Flexible Board.
4
Top View
Disconnect the Iris Flexible Board
from LF-115 Flexible Board.
Rib
Claw
Boss
Claw
Rib
Remove the four screws to detach the Rear Mirror Plate
5
Remove the Gear B (Black), Gear A (White), Gear C (White), Gear D (Black), and Naruto Gear.
6
Screws
Screws
Rear Mirror
Plate
Gear B
(Black)
Gear C
Gear A
(White)
(White)
Naruto
Gear
Gear D
(Black)
DSC-WX50_L2
Boss
Claws
FPC Retainer
Back View
LF-115 Flexible Board
Rib
Remove the 3 Group spring and remove the 3 Group Frame Block Assy..
7
3 Group Frame
Block Assy
3 Group Spring
Turn the Tube Lubricating to the TELE state and remove the Iris Flexible Board from the cutout.
8
Tube
Lubricating
Remove the Main Assy (A) in the WIDE state.
9
Remove the Main Assy (B).
q;
Remove the Tube Lubricating Block Assy and the Shield Ring (C) from the Rotary Tube Block Assy.
qa
Main Assy (B)
1-12
Iris Flexible Board
Cutout
Main Assy (A)
Tube Lubricating
Block Assy
Shield Ring (C)
Rotary Tube
Block Assy

Advertisement

Table of Contents
loading

Table of Contents